Removing and replacing a boot device
Removing and replacing a
The boot device supports two physical drive sizes:
22110 model (110mm)
22080 model (80mm)
Two drives of the same physical size, or one of each size (80mm and 110mm), can be installed at the same time. Depending on the
replacement drive model, you might be required to relocate the M.2 drive retaining latches on the boot device.
Prerequisites
Prerequisites
Review the boot device drive bay LEDs to determine the failed drive.
Procedure
Procedure
1. Observe the following alerts:
CAUTION:
CAUTION:
The boot device and the drives installed on the boot device are not hot-pluggable. To remove the boot device, or a
drive from the boot device, you must first power down the server.
WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the
WARNING:
internal system components to cool before touching them.
2. Back up all server data.
3. Power down the server.
4. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
5. Do one of the following:
a. Extend the server from the rack .
b. Remove the server from the rack .
6. Place the server on a flat, level work surface.
7. Remove the access panel .
8. Remove the riser cage.
9. Remove the boot device.
10. Remove the failed drive from the boot device.
boot device drive
drive
Removing and replacing a boot device drive
132