key. The following message appears:
Only qualified service personnel must modify the serial number. This value must always match the serial number on the chassis.
4. To clear the warning, press the
Enter
key.
5. Enter the serial number and press the
Enter
key.
6. From the System Utilities screen, select System Configuration > BIOS/Platform Configuration (RBSU) > Date and Time.
7. Select a setting, and then complete your entry:
Date (mm-dd-yyyy)—Enter the date in a month-day-year (mm-dd-yyyy) format.
Time (hh:mm:ss)—Enter the time in a 24-hour format (hh:mm:ss) format.
Time Zone—Select your current time zone for the system.
Daylight Savings Time:
Enabled—Adjusts the local time displayed by one hour for Daylight Savings Time.
Disabled—Does not adjust the local time displayed for Daylight Savings Time.
Time Format
Coordinated Universal Time (UTC) — Calculates the time stored in the hardware Real Time Clock (RTC) from the associated
Time Zone setting.
Local Time—Removes the use of the Time Zone setting.
This option is useful for addressing interaction issues between Windows operating systems set in Legacy BIOS boot mode.
8. Save your settings.
9. Select Product ID. The following warning appears:
Warning: The Product ID must ONLY be modified by qualified service personnel. This value must always match the Product ID on the
chassis.
10. Enter the product ID and press the
Enter
key.
11. To confirm exiting System Utilities, press the
F10
key.
12. The server automatically reboots.
Removing and replacing the system board