Removing and replacing an NVDIMM

Removing and replacing an NVDIMM
CAUTION:
CAUTION:
Do not remove an NVDIMM when any LEDs on any NVDIMM in the system are illuminated. Removing an NVDIMM when
an LED is illuminated might cause a loss of data.
CAUTION:
CAUTION:
Electrostatic discharge can damage electronic components. Be sure you are properly grounded before beginning this
procedure.
CAUTION:
CAUTION:
Failure to properly handle DIMMs can cause damage to DIMM components and the system board connector.
To identify NVDIMMs installed in the server, see " NVDIMM identification"
Prerequisites
Prerequisites
Before replacing memory, read the memory configuration and population guidelines in the server user guide.
Procedure
Procedure
1. Observe NVDIMM relocation guidelines.
2. Power down the server.
3. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
4. Do one of the following:
a. Extend the server from the rack .
b. Remove the server from the rack .
5. Remove the access panel .
6. Observe the NVDIMM LEDs. Do not remove an NVDIMM when any NVDIMM LED in the system is illuminated.
7. Remove the NVDIMM-N.
To replace the component, reverse the removal procedure.