HPE ProLiant DL360 Maintenance And Service Manual page 210

Hide thumbs Also See for ProLiant DL360:
Table of Contents

Advertisement

Item
Item
Description
Description
1
1
UID button/LED
2
NIC status LED
1
3
Health LED
1
4
Power On/Standby button
and system power LED
1
When all four LEDs described in this table flash simultaneously, a power fault has occurred.
2
To identify components in a degraded or critical state, see the Systems Insight Display LEDs, check iLO/BIOS logs, and reference the
server troubleshooting guide.
3
Facility power is not present, power cord is not attached, no power supplies are installed, power supply failure has occurred, or the
power button cable is disconnected.
Status
Status
Solid blue = Activated.
Flashing blue:
1 Hz = Remote management or firmware
upgrade in progress.
4 Hz = iLO manual reboot sequence initiated.
8 Hz = iLO manual reboot sequence in progress.
Off = Deactivated.
Solid green = Link to network.
Flashing green = Network active.
Off = No network activity.
Solid green = Normal.
Flashing green = iLO is rebooting.
Flashing amber = System degraded.
Flashing red = System critical.
Solid green = System on.
1
Flashing green = Performing power on sequence.
Solid amber = System in standby.
Off = No power present.
2
3
Front panel LEDs and buttons
210

Advertisement

Table of Contents
loading

Table of Contents