Instructions for Mounting the System

Installation Requirements
The device has an operating temperature range of -40° C to +65° C. Please ensure that the device is mounted
in an area in which acceptable temperature ranges are experienced.
As part of installation best practices, it is recommended to mount the device in the vehicle cabin
area where there is environmental control (i.e. heating and/or air-conditioning). This will extend the
device operating life by not exposing it unnecessarily to adverse environmental conditions.
Please take a moment to read and understand the following important installation conditions to
ensure the Customer Warranty will not be voided.
The device operates between 6V ~ 36V. Please ensure a regulated, consistent power source is
§
available for the device.
DO NOT remove any enclosures/covers associated with the device as this will void the warranty.
§
Remove the In-Line Power fuse prior to jump starting the vehicle.
§
Select a solid ground connection for the device.
§
DO NOT use any third party accessories, unless approved by Gatekeeper Systems.
§
The device is designed for interior use only. Do not install in areas that are exposed to excessive
§
moisture.
Mount the device in a location that has good airflow and is not subject to excessive heat/cold
§
variations. The fan below the recorder must have unobstructed airflow to enable the recorder to cool
properly. Allow at least 6" of clearance all around for effective cooling of the system.
Ensure that the device is mounted where it is not easily accessible by non-authorized personnel.
§
Ensure that ALL provided Split Loom are used around exposed cables. Grommets are to be used as
§
directed by install sheet. Failure to use provided Split Loom and Grommets will void the warranty.
Gatekeeper Systems provides Tek Screws with which to mount the 508HD4 – these have been tested
§
and are approved for mounting.
Power Connection
Plug the power cable into the DC6-36V connector. The device will operate between 6 and 36 volts DC,
§
however the lower the voltage the higher the current. The power source should be clean and
preferably right from the battery or the power bus.
The supplied fuses MUST be used. Failure to protect the system with the correct value fuse may lead
§
to the warranty being voided.
The 3AMP fuse must be installed as close as possible to the power source on the Yellow Ignition wire
§
on CAB000359 or CAB000360.
The 15AMP fuse must be installed as close as possible to the source on the Red (+12V) wire on
§
CAB000359 or CAB000360.
GND
Hardware Installation
(A) (Black)
Connect to the negative terminal of the battery, -12V.