Advanced - Gatekeeper G4-508HD4a User Manual & Installation Manual

Table of Contents

Advertisement

G4-508HD4a User Manual & Install Guide

6.6.3 Advanced

This subsection enables you to set up the trigger for alarm events based on ACC input, and also to define the
actions that will be taken when the alarm occurs.
ACC Alarm
Configuring the G4-508HD4a
Navigate to:
G Sensor
Alarm Type
Trigger
Linkage
Main Menu à Setup à Alarm à Advanced
Checkbox – if selected, enables the device to
monitor for G Sensor trigger events. In case of G
Sensor exceeding the threshold values, this alarm
will be triggered.
DEFAULT SETTINGS:
Checkbox – Unselected
§
Drop list to select the classification level for the
alarm:
Event
§
Alarm
§
DEFAULT SETTINGS:
Click the ( Setup ) button under Trigger to display
the Trigger setup screen to setup the ACC
threshold values:
X – numeric text field to set the threshold
§
value for the G forces along the x-axis.
Y – numeric text field to set the threshold
§
value for the G forces along the y-axis.
Z – numeric text field to set the threshold
§
value for the G forces along the z-axis.
DEFAULT SETTINGS:
Disabled.
Click the ( Setup ) button under Linkage to go to
the Linkage setup screen. This sets up the video
display,
recording
and
associated with this alarm.
The Linkage setup screen enables you to
configure the following options:
Channel – checkboxes which allow you
§
to select any combination of the camera
channels to be included in the display
and recording.
snapshot
options