Unique Programming for Non-pager Message Notification
Step 1
Set the intervals IntraMail will wait between incomplete non-pager Message Notification
callouts.
1.1
1.2
1.3
1.4
Step 2
Set how IntraMail determines when a non-pager callout rings without being answered.
2.1
IntraMail System Guide
8004 - IntraMail System Options: Wait Between Non-Pager Callout Attempts on page 215.
- Set the minimum time (1-255 minutes) between non-pager Message Notification callouts in
which the destination answers, says "Hello," dials 1 to acknowledge and then enters the
wrong security code.
The default for this option is 20 minutes.
8004 - IntraMail System Options: Wait Between Busy Non-Pager Callout Attempts on
page 215.
- Set how long IntraMail will wait (1-255 minutes), after it dials a busy non-pager callout
destination, before retrying the callout number.
The default for this option is 15 minutes.
8004 - IntraMail System Options: Wait Between RNA Non-Pager Callout Attempts on
page 215.
- Set how long IntraMail will wait (1-255 minutes), after it dials an unanswered non-pager
callout destination, before retrying the callout number. The default setting for this option is
30 minutes.
- There are three types of unanswered non-pager callouts:
- If the callout rings the destination longer than the 8004-Wait for Answer Non-Pager
Callout Attempts.
- If the destination answers, says "Hello" (or the system detects answer supervision)
and then hangs up without dialing 1 to log onto their mailbox. This typically hap-
pens if someone unfamiliar with notification answers the callout, or if the callout is
picked up by an answering machine.
- If the destination answers and then hangs up without saying "Hello." This typically
happens if someone unfamiliar with the notification answers the callout (like the
above example), or if the call is picked up by an answering machine which insuffi-
cient outgoing message volume.
The default for this option is 30 minutes.
8004 - IntraMail System Options: Wait for Answer Non-Pager Callout Attempts on page 216.
- If a non-pager callout rings the destination longer than this option (1-99 rings), IntraMail
marks the call as unanswered (Ring No Answer) and hangs up.
The default for this option is 5 rings.