Getting Started
and <Elevation Check Point: Left>. The selected spot on the milling head is then measured
or brought directly in relation to the control point hub.
The <Reference Point Elevation> is manually entered by the operator.
the sensor starts measuring. This may take a few seconds as several measure-
ments are taken during this time.
The <Measured Check Point Elevation> is the current elevation of the milling head, meas-
ured with the GPS sensor.
The difference between the measurement and the reference point elevation is the <Current
Sensor Elevation Offset>.
stores the current sensor elevation offset. From now on this offset is considered
in the calculation until a new offset is determined with the Bench function again.
continues and rejects the currently determined offset. The previously used offset
will be used again.
PaveSmart 3D UM 71