Troubleshooting

4
Troubleshooting
Troubleshooting
Problem
Possible cause(s)
Computer does
Inadequate or missing power
not boot or start
supply
up or keeps
Power regulator failed
rebooting
Reversed power supply polarity
Damaged Machine Computer
Damaged power cable
Leica PaveSmart
Auto-Start is not enabled
3D does not start
Configuration corrupted
Configuration is
Configuration corrupted
lost or strange
behaviour of Leica
PaveSmart 3D
Robot fails to
Communication parameters on
initialise
instrument are not set correctly
Baud rate is not identical on
instrument and in the software
Radio modems have not the same
Link/baud rate configuration
• Low battery at instrument
PaveSmart 3D UM 100
Suggested remedies
Check machine power supply, fuses
and voltage regulator
Check connections to the MPC1310
Contact Leica Geosystems
Check all cables for damage
Restore Auto-Start link
Copy backup from USB storage
device
Restore back up in the Projects
menu
Choose appropriate Config Set
(TCRP RCS-RH1200 or TCRP RCS-
TCPS27)
Green LED's on a radio modem pair
need to be On
Configure radio modems to the
same Link/baud rate configuration
• Instrument is in a configuration
menu or in As-Built menu