Scm Operating Values Chart - Skyjack SJ82 T Service Manual

Telescopic booms
Hide thumbs Also See for SJ82 T:
Table of Contents

Advertisement

Section 5 – Procedures

5.2-4 SCM Operating Values Chart

Input
AI 1
AI 2
AI 3
AI 4
DI 1
DI 2
DI 3
DI 4
DI 5
DI 6
DI 11
Output
PWM 1
PWM 2
PWM 3
PWM 4
PWM 5
PWM 6
PWM 7
PWM 11
PWM 12
Output
DOUT 1
DOUT 2
DOUT 3
DOUT 4
DOUT 5
229040ABA
168
Expected Value
0.5V to 8.5V
0.5V to 8.5V
0.5V to 8.5V
0.5V to 7.5V
0 or 1
0 or 1
0 or 1
0 or 1
0 or 1
0 or 1
0 or 1
Adjustable Parameter
25 to 75%
25 to 75%
21 to 35%
21 to 35%
21 to 35%
38 to 47%
0 to 100%
40 to 48%
45 to 70%
Expected Value
0 or 1
0 or 1
0 or 1
0 or 1
0 or 1
Description
Drive Joystick
Turret Rotation Joystick
Boom Elevation Joystick
Flow Enable Rotary Potentiometer
Direction Reverse Limit Switch
Footswitch Actuated
Telescope Out Toggle Switch
Telescope In Toggle Switch
Jib Toggle Enabled
Platform Rotation Toggle Enabled
High Speed Drive Enable Limit Switch
Description
Drive Reverse
Drive Forward
Turret Rotate Left
Turret Rotate Right
Main Boom Down
Main Boom Up
Jib and Platform Rotate
Boom Telescope Retract
Boom Telescope Extend
Description
Steering Reverse Relay
Load Sense Valve Enable
Footswitch Actuated Indicator
Holding Brake OFF (energize to release)
Manual Platform Level Enable
Platform
1371AA
SJ82 T, SJ86 T

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sj86 t