Skyjack SJ82 T Service Manual page 224

Telescopic booms
Hide thumbs Also See for SJ82 T:
Table of Contents

Advertisement

Deutz Diesel Engines
5.6-6 Deutz TD2.9L Fault Codes
Code SPN FMI Blink Code
720
98
2
732
100
3
733
100
4
734
100
0
735
100
0
736
100
1
737
100
1
743
175
3
744
175
4
745
175
0
746
175
0
747
1237
2
750
107
3
751
107
0
752
107
0
753
523919
2
755
523919
0
758
523919
1
761
523919
3
762
523919
4
763
523920
2
765
523920
0
770
523920
3
771
523920
4
772
102
2
774
102
1
776
102
3
777
102
4
780
523699
3
781
523699
4
785
523889
3
SJ82 T, SJ86 T
Plausibility Check.
2-1-1
No detailed information!
2-2-4
Sensor error oil pressure; signal range check high.
2-2-4
Sensor error oil pressure sensor; signal range check low.
2-3-1
High oil pressure; warning threshold exceeded.
2-3-1
High oil pressure; shut off threshold exceeded.
2-3-1
Low oil pressure; warning threshold exceeded.
2-3-1
Low oil pressure; shut off threshold exceeded.
1-4-4
Sensor error oil temperature; signal range check high.
1-4-4
Sensor error oil temperature; signal range check low.
1-4-4
High oil temperature; warning threshold exceeded.
1-4-4
High oil temperature; shut off threshold exceeded.
1-4-5
Override switch; plausibility error.
1-3-6
Sensor error airfilter differential pressure; short circuit to battery.
1-3-6
Sensor error airfilter differential pressure; short circuit to ground.
1-3-6
Air filter differential pressure; air filter cologged.
6-9-4
DPF burner air pump pressure sensor, plausibility error.
DPF burner air pump pressure sensor, pressure above upper shutoff
6-9-4
threshold.
DPF burner air pump pressure sensor, pressure below lower shutoff
6-9-4
threshold.
6-9-4
DPF burner air pump pressure sensor, short circuit to battery or open load.
6-9-4
DPF burner air pump pressure sensor, short circuit to ground.
7-1-6
Exhaustgaspressure upstream burner, plausibility error.
Exhaust gas pressure upstream burner, pressure above upper shutoff
7-1-6
threshold.
7-1-6
Exhaust gas pressure upstream burner, short circuit to battery or open load.
7-1-6
Exhaust gas pressure upstream burner, short circuit to ground.
2-2-3
Pressure downstream charge air cooler, plausibility error.
Pressure downstream charge air cooler, pressure below lower physical
2-2-3
threshold.
2-2-3
Pressure downstream charge air cooler, short circuit to battery or open load.
2-2-3
Pressure downstream charge air cooler, short circuit to ground.
1-1-3
Boost pressure control; negative governor deviation below limit.
1-1-3
Learning value too high. No detailed information!
Over temperature of device driver of pressure control valve. No detailed
1-1-3
information!
Error Identification
Section 5 – Procedures
1513AA-9
229040ABA
229