27 Lift Cushion Limit Switch (Ls6) - Skyjack SJ82 T Service Manual

Telescopic booms
Hide thumbs Also See for SJ82 T:
Table of Contents

Advertisement

Section 5 – Procedures

5.4-27 Lift Cushion Limit Switch (LS6)

LS6 slows the raising boom speed before the main lift
cylinder reaches the stop at full extension.
LS6 is normally closed. As the lift cylinder approaches
full extension, the switch roller makes contact with
the master cylinder link. The switch trips to open the
circuit.
LS6 is located on the inside of the turret on the left-
hand side, near the lower end of the master cylinder
link.
LS6 location inside turret
WARNING
Ensure there are no personnel or obstructions in
the test area and there is sufficient room to raise
the boom.
Check Switch Operation:
1. Position the main boom horizontal. Use a level
to verify.
2. Place a digital protractor on a clean surface on
the underside of the main boom. Calibrate it to
0° (horizontal).
3. Locate the terminal strip inside the base control
panel. Set the multi-meter to continuity-check
mode.
229040ABA
210
4. Place the multi-meter probes on terminal
positions (19 black/white) and (09 black). The
multi-meter should show the circuit is closed
(continuity).
09
Black
M62348AA
5. Raise the boom up all the way until the lift
cylinder is fully extended. Observe if speed
slows (LS6 has tripped) when the boom angle
reaches 57°.
6. Check the multi-meter reading. There should be
no continuity when the switch trips.
19
Black/White
LS6 terminal connections
Boom
M62346AA
SJ82 T, SJ86 T