Deutz Diesel Engines
5.6-6 Deutz TD2.9L Fault Codes
Code SPN FMI Blink Code
1219
524018
14
1220
524022
14
1222
190
14
1223
51
5
1224
51
6
1226
51
3
1227
51
3
1228
51
4
1229
51
4
1230
51
6
1231
51
11
1232
51
4
1239
523984
3
1241
523986
4
1242
523987
4
1247
524019
11
1248
523910
9
1249
523910
7
1250
523910
12
1252
523910
0
1254
524014
1
1255
524013
7
1257
523915
7
1258
524016
11
1259
524016
2
1261
523910
6
1262
523922
7
1263
524021
11
SJ82 T, SJ86 T
HMI engine derate service state.
7-8-6
DPF wasn't regenerated, power reduction phase 1 (manuell regeneration
request).
HMI engine derate stop state.
7-8-6
DPF wasn't regenerated, power reduction phase 2 (manuell regeneration
request).
2-1-2
Camshaft- and Crankshaft speed sensor signal not available on CAN.
5-9-4
Actuator EGR-Valve (2.9;3.6) or Throttle-Valve (4.1;6.1;7.8); open load.
5-9-4
Actuator EGR-Valve (2.9;3.6) or Throttle-Valve (6.1,7.8); over current.
5-9-4
EGR-Valve (2.9;3.6) or Throttle-Valve (4.1;6.1;7.8); short circuit to battery.
5-9-4
EGR-Valve (2.9;3.6) or Throttle-Valve (4.1;6.1;7.8); short circuit to battery.
5-9-4
EGR-Valve (2.9;3.6) or Throttle-Valve (4.1;6.1;7.8); short circuit to ground.
5-9-4
EGR-Valve (2.9;3.6) or Throttle-Valve (4.1;6.1;7.8); short circuit to ground.
Actuator error EGR-Valve (2.9;3.6) or Throttle-Valve (4.1;6.1;7.8); Overload by
5-9-4
short-circuit.
5-9-4
Power stage overtemperature due to high current.
actuator AGR valve (2.9;3.6) throttle valve (4.1;6.1;7.8); Voltage below thresh-
5-9-4
old.
7-8-8
UB7; Short circuit to battery error of actuator relay 7.
1-7-6
UB6; Short circuit to ground actuator relais 6.
7-9-1
UB7; Short circuit to ground actuator relay 7.
8-6-2
Burner Control; Air Line - Blocked Air Pump; air lines blocked.
6-9-5
Burner Control; Air Pump - CAN Lost Air Pump; CAN communication lost.
6-9-5
Air pump; CAN communication interrupted no purge function available.
6-9-5
Air Pump; internal error.
6-9-5
Air Pump; operating voltage error.
Air inlet EPV - pressure too low.
8-5-8
Air pressure glow plug flush line; below limit.
Burner Control; Flame lost max.
8-5-7
Burner operation is interrupted too often.
8-5-3
HCI dosing valve (DV1); blocked open.
8-5-9
Burner Control; HFM - Electrical Fault HFM sensor; electrical fault.
Burner Control; HFM - Plausibilitätsfehler 1 Amount of air is not plausible to
8-5-9
pump speed.
6-9-5
Burner Control Air Pump; over current Air pump electrically overloaded.
Burner Control; Shut-off Valve - Blocked closed Burner Shut Off Valve;
8-5-4
blocked closed.
Burner Control; Fuel line ShutOff downstream - broken Burner fuel line pipe
8-6-4
leak behind Shut Off Valve.