Skyjack SJ82 T Service Manual page 235

Telescopic booms
Hide thumbs Also See for SJ82 T:
Table of Contents

Advertisement

Section 5 – Procedures
5.6-6 Deutz TD2.9L Fault Codes
Code SPN FMI Blink Code
1759
2791
4
1760
2791
13
1761
2791
7
1762
2791
16
1763
2791
0
1788
1188
7
1789
1188
2
1790
1188
13
1791
1188
12
1792
1188
13
1793
1188
6
1794
1188
3
1795
1188
4
1796
1188
13
1797
1188
7
1799
1188
0
1827
524141
7
1857
523612
12
1858
524147
7
229040ABA
240
4-1-5
EGR actuator supply voltage is below minimum threshold.
4-1-5
EGR actuator, learning process out of range.
4-1-5
EGR actuator, broken spring detected.
4-1-5
EGR actuator, temperature high.
4-1-5
EGR actuator, temperature critical high.
8-1-4
Turbocharger wastegate, mechanical blocking detected.
8-1-4
Turbocharger wastegate, CAN Error.
8-1-4
Turbocharger wastegate, EOL calibration error.
8-1-4
Turbocharger wastegate, internal electrical error.
8-1-4
Turbocharger wastegate, learning process aborted.
8-1-4
Turbocharger wastegate, current above maximum threshold.
8-1-4
Turbocharger wastegate, supply voltage above maximum threshold.
8-1-4
Turbocharger wastegate, supply voltage below minimum threshold.
8-1-4
Turbocharger wastegate, learning process out of range.
8-1-4
Turbocharger wastegate, broken spring detected.
8-1-4
Turbocharger wastegate, temperature critical high.
1-9-2
DEF dosing valve, dosing valve blocked.
5-5-5
Engine starter, plausibility error of starter release condition.
9-6-6
SCR-System, reverting valve blocked.
Error Identification
Deutz Diesel Engines
1513AA-20
SJ82 T, SJ86 T

Advertisement

Table of Contents
loading

This manual is also suitable for: