Section 5 – Procedures
5.6-6 Deutz TD2.9L Fault Codes
Code SPN FMI Blink Code
1023
51
5
1024
51
3
1025
51
4
1026
4769
2
1029
4766
0
1030
4766
0
1034
4769
3
1035
4769
4
1036
4768
2
1039
4765
0
1040
4765
0
1044
4768
3
1045
4768
4
1047
3248
4
1067
1180
3
1069
4360
0
1070
4360
1
1071
4361
2
1166
523948
1
1167
523949
1
1168
523950
1
1170
523612
12
1180
168
0
1181
168
1
1183
172
1
1187
523980
14
1193
1180
0
1194
1180
1
229040ABA
234
Actuator error EGR-Valve (2.9;3.6) or Throttle-Valve (4.1;6.1;7.8); signal range
5-9-4
check low.
Position sensor error of actuator EGR-Valve (2.9;3.6) or Throttle-Valve
5-9-4
(4.1;6.1;7.8).
Signal range check high.
Position sensor error actuator EGR-Valve (2.9;3.6) or Throttle-Valve
5-9-4
(4.1;6.1;7.8).
Signal range check low.
6-8-4
Temperature downstream DOC, plausibility error.
6-8-4
Temperature downstream DOC, temperature above upper shutoff threshold.
6-8-4
Temperature downstream DOC, temperature above upper warning threshold.
Sensor error exhaust gas temperature downstream (DOC); signal range
6-8-4
check high.
Sensor error exhaust gas temperature downstream (DOC); signal range
6-8-4
check low.
6-8-3
Temperature upstream DOC, plausibility error.
6-8-3
Temperature upstream DOC, temperature above upper shutoff threshold.
6-8-3
Temperature upstream DOC, temperature above upper warning threshold.
Electrical error exhaust gas temperature upstream (DOC); signal range
6-8-3
check high.
Electrical error exhaust gas temperature upstream (DOC); signal range
6-8-3
check low.
6-8-5
Sensor error particle filter downstream temperature; signal range check low.
Sensor error exhaust gas temperature upstream turbine; signal range check
5-5-6
high.
Exhaust temperature upstream SCR-Cat, temperature above upper physical
6-6-8
threshold.
6-6-8
Sensed exhaust temperature before SCR-Cat is < physical low limit.
6-6-8
Signal error for CAN message No detail informationen!
7-7-2
Zerofuel calibration injector 3 (in firing order); minimum value exceeded.
7-7-2
Zerofuel calibration injector 4 (in firing order); minimum value exceeded.
7-7-2
Zerofuel calibration injector 5 (in firing order); minimum value exceeded.
5-5-5
Internal software error ECU.
3-1-8
Physical range check high for battery voltage.
3-1-8
Physical range check low for battery voltage.
2-2-6
Air inlet filter sensor out of physical range check.
7-8-4
Bad quality of reduction agent detected.
5-5-6
Physical range check high for exhaust gas temperature upstream turbine.
5-5-6
Physical range check low for exhaust gas temperature upstream turbine.
Error Identification
Deutz Diesel Engines