Deutz Diesel Engines
5.6-6 Deutz TD2.9L Fault Codes
Code SPN FMI Blink Code
857
523613
0
858
523613
0
859
523613
0
861
523613
1
862
523613
0
864
523613
2
865
523613
0
874
157
0
875
157
1
876
523470
7
877
157
3
878
157
4
881
523633
11
882
523633
11
883
523633
11
887
3234
11
889
3224
1
892
4345
11
893
4343
11
894
4374
13
897
523632
16
898
523632
18
899
523632
0
900
523632
1
903
4365
0
905
3241
0
908
3361
7
914
523720
2
915
523720
2
SJ82 T, SJ86 T
Rail pressure metering unit, Rail pressure disrupted. Maximum positive
1-3-4
deviation of rail pressure exceeded.
Rail pressure metering unit, Rail pressure disrupted. Maximum positive
1-3-4
deviation of rail pressure in metering unit exceeded (RailMeUn1).
Rail pressure metering unit, Rail pressure below the target range.
1-3-4
(RailMeUn2)
Railsystem leakage detected.(RailMeUn10)
Rail pressure metering unit, Minimum rail pressure exceeded (RailMeUn3).
1-3-4
Negative deviation of rail pressure second stage (RailMeUn22).
1-3-4
Rail pressure metering unit, Maximum rail pressure exceeded.
Rail pressure metering unit, Setpoint of metering unit in overrun mode not
1-3-4
plausible.
1-3-4
Setpoint of metering unit in overrun mode not plausible.
1-4-7
Rail pressure raw value is intermittent. No detailed information!
1-4-7
rail pressure raw value is above maximum offset. No detailed information!
1-4-6
Maximum rail pressure exceeded (PRV).
1-4-7
Sensor error rail pressure. Sensor voltage above upper limit.
1-4-7
Sensor error rail pressure. Sensor voltage below lower limit.
1-4-9
Longterm adaption factor below threshold.
1-4-9
Nox conversion rate insufficient (SCR-Cat defect, bad DEF quality).
Nox conversion rate insufficient (SCR-Cat defect, bad DEF quality);
1-4-9
temperature range 1
1-8-4
DFC for plausibility error Min for NOx sensor downstream of SCR Cat.
1-8-5
DFC for plausibility error Max for NOx sensor upstream of SCR Cat.
2-3-6
Sensor backflow line pressure (SCR); plausibility error.
SCR Monitoring; Pressure stabilisation error, general pressure check error
8-7-1
(SCR).
8-7-2
Pressure stabilisation error dosing valve (SCR).
8-7-5
Pump pressure SCR metering unit too high.
8-7-6
Pump pressure SCR metering unit too low.
8-7-7
Pressure overload of SCR-System.
8-7-8
Pressure build-up error SCR-System.
8-8-1
DEF tank temperature too high.
8-8-3
Sensor SCR catalyst upstream temperature too high; plausibility error.
8-8-6
DEF dosing valve blocked (SCR).
1-4-8
DEF supply module heater temperature; plausibility error (normal condition).
Sensor DEF supply module heater temperature; plausibility error (cold start
1-4-8
condition).
Error Identification
Section 5 – Procedures
1513AA-11
229040ABA