Section 5 – Procedures
5.5-9 Resetting the Emergency Lowering
Counter (CE only)
The emergency lowering counter increments each
time the emergency power unit is activated while the
platform is in work mode and overloaded.
To reset the counter:
1. Locate the terminal block with the integrated
fuse holder inside the base control box.
2. Using any standard automotive fuse, insert it into
the slot in the terminal block.
229040ABA
218
3. Remove the fuse.
4. Check the counter on the base control box door
to verify it has been reset to zero.