Skyjack SJ82 T Service Manual page 234

Telescopic booms
Hide thumbs Also See for SJ82 T:
Table of Contents

Advertisement

Deutz Diesel Engines
5.6-6 Deutz TD2.9L Fault Codes
Code SPN FMI Blink Code
1677
524106
9
1678
524107
9
1679
524109
9
1680
524111
9
1681
524113
9
1682
524120
9
1683
524121
9
1684
524122
9
1685
524123
9
1686
524124
9
1687
524125
9
1698
524133
2
1699
524134
0
1700
524134
0
1701
524135
0
1702
524135
14
1703
524135
0
1705
524156
9
1706
524157
9
1708
524159
0
1709
524159
1
1710
524160
5
1712
524160
3
1713
524160
4
1714
524161
5
1716
524161
3
1717
524161
4
1718
524162
12
1719
524163
12
1752
2791
7
1753
2791
2
1754
2791
13
1755
2791
12
1756
2791
13
1757
2791
6
1758
2791
3
SJ82 T, SJ86 T
1-9-5
Timeout error of CAN-Receive-Frame ComRxEGRMsFlw1 (EGR actuator)
9-3-1
Timeout error of CAN-Receive-Frame ComRxEGRMsFlw2 (EGR actuator).
9-3-3
Timeout error of CAN-Receive-Frame ComRxEGRTVActr (EGR actuator).
9-3-5
Timeout error of CAN-Receive-Frame ComRxETVActr.
9-3-7
Timeout error of CAN-Receive-Frame ComRxITVActr.
9-4-4
Timeout error of CAN-Receive-Frame ComRxSCRHtDiag.
9-4-5
Timeout error of CAN-Receive-Frame ComRxTrbChActr (wastegate actuator).
9-4-6
Timeout error of CAN-Receive-Frame ComRxUQSens (Urea quality).
9-4-7
Timeout error of CAN-Receive-Frame ComSCRHtCtl.
9-4-8
Timeout error of CAN-Receive-Frame ComTxAT1IMG.
9-4-9
Timeout error of CAN-Receive-Frame ComTxTrbChActr (Wastegate actuator).
9-5-6
HMI system; set if restore button blocked.
9-5-7
DPF, ash load exceeds the shutoff threshold.
9-5-7
DPF, ash load exceeds the warning threshold.
9-5-8
DPF, soot load exceeds the shutoff threshold.
9-5-8
DPF, soot load exceeds the service request threshold.
9-5-8
DPF, soot load exceeds the warning threshold.
9-7-2
Timeout error of CAN-Receive-Frame ComRxEBC2.
9-7-3
Fan control; time out for fan governing.
9-7-5
Fan; short circuit battery or open load.
9-7-5
Fan; short circuit ground.
9-7-6
Fan; in/outlet valve 1; open load.
9-7-6
Fan; in/outlet valve 1; short circuit battery.
9-7-6
Fan; in/outlet valve 1; open load ground.
9-7-7
Fan; in/outlet valve 2; open load.
9-7-7
Fan; in/outlet valve 2; short circuit battery.
9-7-7
Fan; in/outlet valve 2; open load ground.
9-7-8
Fan; fancontrol; angle sensor defect.
9-7-9
Fan; fancontrol; fan or valve defect.
4-1-5
EGR actuator, actuator blocked.
4-1-5
EGR actuator, CAN error.
4-1-5
EGR actuator, EOL calibration error.
4-1-5
EGR Actuator, internal electrical fault.
4-1-5
EGR actuator, learning process aborted.
4-1-5
EGR actuator current is above maximum threshold.
4-1-5
EGR actuator supply voltage is above the maximum threshold.
Error Identification
Section 5 – Procedures
1513AA-19
229040ABA
239

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sj86 t

Table of Contents