Q511: System Low Battery Reports To Cs; Q512: System Low Battery Restore Reports To Cs; Q513: Rf Low Battery Reports To Cs; Q514: Sensor Low Battery Restore Reports To Cs - 2gig Technologies EDGE Installation Manual

Security & smart home system
Hide thumbs Also See for EDGE:
Table of Contents

Advertisement

Q511: System low battery reports to CS

Configures the system to transmit low battery reports about the 2GIG EDGE Panel to the Central Station.
Choose one of these options:
»
† Enabled: The system transmits a report to the Central Station.
»
Disabled: The system does not transmit a report to the Central Station.

Q512: System low battery restore reports to CS

Configures the system to transmit a report to the Central Station after a low battery condition on the 2GIG EDGE Panel is restored.
Choose one of these options:
»
† Enabled: The system transmits a report to the Central Station.
»
Disabled: The system does not transmit a report to the Central Station.

Q513: RF low battery reports to CS

Configures the system to transmit low battery reports about the system's sensors and peripherals to the Central Station.
Choose one of these options:
»
† Enabled: The system transmits a report to the Central Station.
»
Disabled: The system does not transmit a report to the Central Station.

Q514: Sensor low battery restore reports to CS

Configures the system to transmit a report to the Central Station after a low battery condition for a sensor is restored.
Choose one of these options:
»
† Enabled: The system transmits a report to the Central Station.
»
Disabled: The system does not transmit a report to the Central Station.

Q515: System disarmed reports to CS

Configures the system to transmit a report to the Central Station when the system is disarmed by a user. The report includes the keyfob or user
code that disarmed the system.
Choose one of these options:
»
Enabled: The system transmits a report to the Central Station.
»
† Disabled: The system does not transmit a report to the Central Station.
NOTE: Arming setting on Alarm.com monitoring settings supersedes Q515: System disarmed reports to CS

Q516: System armed reports to CS

Configures the system to transmit a report to the Central Station when the system is disarmed by a user. The report includes the keyfob or user
code that disarmed the system.
Choose one of these options:
»
Enabled: The system transmits a report to the Central Station.
»
† Disabled: The system does not transmit a report to the Central Station.
NOTE: Arming setting on Alarm.com monitoring settings supersedes Q516: System armed reports to CS

Q517: Alarm restore reports to CS

Configures the system to transmit reports to the Central Station after an alarm, either when the Bell Cutoff Time expires or when the system is
disarmed.
You have these options:
»
Enabled: The system transmits a report to the Central Station. Depending on the number of trips set for a cross sensor zone, the
feature works as follows:
»
If enabled and
Q208
normal state) at the Bell Cutoff Time or if the sensor is closed after the Bell Cutoff Time.
»
If enabled and
Q208
disarmed. Reports are not sent if a sensor is in swinger shutdown until the time of disarm and the sensor is closed.
»
† Disabled: The system does not transmit a report to the Central Station.
NOTE: Alarms setting on Alarm.com monitoring settings supersedes Q517: Alarm restore reports to CS.
on page 1 is set to two (2) trips, the system transmits a report when the triggering sensor is closed (i.e., in its
on page 1 is set to one (1) trip, the system transmits a report only if the sensor is closed at the time the system is