Q407: Trouble doesn't sound at night

Prevents audible trouble alerts from waking users during nighttime hours. When this feature is turned ON, audible trouble alerts are suppressed
between the pre-configured hours of 10:00 PM - 9:00 AM. This setting does not suppress any other trouble alert features. The system will
continue to display trouble alert messages on the touchscreen.
It will also continue to transmit trouble reports to the Central Station, as well as to log trouble alerts in the system's Alarm History.
If the reported trouble condition clears on its own or a user acknowledges the condition(s) on the Control Panel before 9:00 AM, no trouble tones
will sound after 9:00 AM. However, the trouble condition is recorded in the system's Alarm History.
Choose one of these options:
»
† Enabled: Turns the feature ON.
»
‡ Disabled: Turns the feature OFF. For compliance with UL 985: Household Fire Warning System Units, this setting must be disabled.

Q408: RF jam causes trouble

Configures the system to activate a trouble condition when the wireless receiver in the 2GIG EDGE Panel detects that one of the system's RF
transmitters is causing an RF jam. For this setting to go into affect, you must also enable
Choose one of these options:
»
Enabled: The system detects RF jamming.
»
† Disabled: The system does not detect RF jamming.

Q409: System tamper causes trouble

Configures the system to activate a trouble condition if one of the tamper switches on the 2GIG EDGE Panel (wall tamper switch or cell radio
tamper switch) is triggered while the system is disarmed. The system will also activate an alarm condition if a tamper switch is triggered while
the system is armed.
You have these options:
»
† Enabled: The system activates a trouble condition.
»
Disabled: The system does not activate a trouble condition.

CS Reporting

Q501: CS lack of usage notification time, in days

Configures the system to monitor itself for lack of usage. If the system is not armed for the number of days you specify here, an inactivity report is
sent to the Central Station.
Choose one of these options:
»
0 Days: Turns this feature OFF.
»
1-255 Days: Turns this feature ON and transmits an inactivity report to the Central Station after the specified number of days.
»
† 7 Days: Turns this feature ON and transmits an inactivity report to the Central Station after seven (7) days of inactivity.

Q502: Periodic test, in days

Configures the system to automatically transmit periodic test reports about the panel's connections to the Central Station at the recurring interval
you specify here.
Choose one of these options:
»
0 Days: Turns the feature OFF. The system does not transmit periodic test reports to the Central Station.
»
1-255 Days: Turns the feature ON. The system transmits periodic test reports to the Central Station at recurring intervals using the
number of days specified here.
»
† 30 Days: Turns the feature ON. The system transmits periodic test reports to the Central Station once every 30 days.

Q503: Programming mode entry reports to CS

Configures the system to transmit programming reports to the Central Station. When enabled, this setting automatically transmits a report to the
Central Station when programming mode is started and terminated.
Choose one of these options:
»
Enabled: The system transmits a report to the Central Station.
»
† Disabled: The system does not transmit a report to the Central Station.
NOTE: Programming access setting on Alarm.com monitoring settings supersedes Q503 Programming mode entry reports to CS.
Q504: Trouble reports to CS
53
.