Q108: Z-Wave feature

Configures the system to show or hide the Smart Home Controls button on Home screen of the touchscreen. When this feature is enabled, it
provides users with access to the smart devices on the network.
Choose one of these options:
»
Disabled and Hidden: Hides the Smart Home Controls button on the Home screen.
»
Disabled but Visible: Shows the Smart Home Controls button on the Home screen. When a user taps the button, the This feature is
not currently activated message displays.
»
† Enabled: Shows the Smart Home Controls button on the Home screen. Users can operate smart devices from the touchscreen or
remotely.

Q109: Master user can access Z-Wave setup

Configures the system to allow persons who know the system's Master User Code to gain access to the System Settings > Smart Home Settings menu.
Choose one of these options:
»
Enabled: This makes the Smart Home Settings button available in the System Settings menu after entering the Master User Code.
»
† Disabled: This grays out the Smart Home Settings button and makes it unavailable in the System Settings menu.

Q110: Smart Home Controls require master code

Configures the system to prompt the user for the master code when attempting to access the Smart Home Controls menu (if enabled). See
above.
Z-Wave feature
Choose one of these options:
»
Enabled: When a user taps the Smart Home Controls button, the Enter Your Code to Access Smart Home
»
Controls screen appears.
»
† Disabled: Opens the Smart Home Controls menu, without prompting the user for a code.

Q111: Main Panel Sounder Follows

Configures the system to allow alarms in all Smart Areas to sound the Main panel.
Choose one of these options:
»
† All Smart Areas: Alarms from any Smart Area will alert and sound at the 2GIG EDGE Panel.
»
Main Panel Smart Area Only: Only alarms in Smart Area 1 will alert at the 2GIG EDGE Panel, alarms in Smart Areas 2-4 will only
alert on keypads assigned to those areas.
NOTE: With both options alarms for all Smart Areas are visible by entering the Smart Areas Screen via the Home Screen button.

Q112: Z-Wave siren mode

Configures the system to sound any Z-Wave sirens that have been added to the network.
Choose one of the options:
»
† Sound for Burglary and Fire/CO: Configures the system to sound any connected Z-Wave sirens during a burglary, fire, or CO
alarm.
»
Sound for Burglary Only: Configures the system to sound any connected Z-Wave sirens during burglary alarms only.

Q113: Quick arming

Turns the system's quick arming feature ON and OFF. This feature can be assigned individually for each Smart Area. (Smart Areas feature must
be enabled (Q107) for settings for S2-S4 to affect the system) When ON, any occupant can arm the system. When OFF, only persons who know an
active user code can arm the system.
Choose one of these options:
»
† Enabled: Turns the feature ON and does not require occupants to enter a user code to arm the system.
»
Disabled: Turns the feature OFF and requires occupants to enter an active, user code or Face Recognition (if enabled) to arm the
system.

Q114: Auto stay

Turns the system's Auto Stay feature ON and OFF. This feature can be assigned individually for each Smart Area. (Smart Areas feature must be
enabled (Q107) for settings for S2-S4 to affect the system) When ON, the system monitors the Exit Delay doors after the user arms the system in
Away Mode at the 2GIG EDGE Panel. If no one exits that door before the Exit Delay countdown expires, the system automatically arms itself in Stay
Mode.
, in seconds (45-120). This setting does not go into effect when arming the system in Away Mode with a keyfob or from
See Q201: Exit delay