Ansi/Sia Cp-01-2010 Features To Limit False Alarms - 2gig Technologies EDGE Installation Manual

Security & smart home system
Hide thumbs Also See for EDGE:
Table of Contents

Advertisement

ANSI/SIA CP-01-2010 Features to Limit False Alarms

For compliance with ANSI/SIA CP-01-2010: Control Panel Standard - Features for False Alarm Reduction, the installer can set a variety of
different options designed to limit occurrences of a False Alarm.
ANSI/SIA CP-01-2010
4.2.2.1
Exit Time
4.2.2.2
Progress Annunciation
4.2.2.3
Exit Time Restart
4.2.2.4
Exit Error
4.2.2.5
Unvacated Premises
4.2.3.1
Entry Delay
4.2.3.2
Progress Annunciation
4.2.3.3
Disarm
4.2.4.1
Control Buttons
4.2.4.2
Manual Alarms
4.2.4.3
System Acknowledgment
4.2.4.4
Remote Arming
4.3.4.5
Remote Disarming
4.2.5.1
Abort Window
4.2.5.1.1
Disarm
4.2.5.1.2
Abort
4.2.5.2
Alarm Transmission
4.2.5.3
Disarm
4.2.5.4
Cancel Window
4.2.6.1
Use of Duress Feature
4.2.6.2
Duress Code
4.2.7
Initiation of Manual Alarms
4.3.
Cross Zoning
4.3.2
Swinger Shutdown
4.3.3
Fire Alarms
4.6.3
System Test
Installation Guide for the 2GIG EDGE Security Panel
2GIG System Feature
Exit Delay
Exit Delay Announcement
Exit Delay Restart
Exit Error
Auto Stay
Entry Delay
Entry Delay Announcement
Disarming Features
Keyfob/Remote Arming Mode on System Not Ready.
Emergency Alarm Features
Alert Keyfob Disarming After Alarm
Keyfob Arm/Disarm Confirmation
Key Fob Arming
Key Fob Arming
Abort Window Dialer Delay
Abort Window Dialer Delay
Abort Window Dialer Delay
Abort Window Dialer Delay
Disarm
Alarm Cancel Time, Alarm Cancel Display
User Duress Report
Duress Code
Panic, Fire, or Emergency Alarm
Cross Sensor Zones, Cross Sensor Timeout
Swinger Shutdown Count (1-6)
Fire & Carbon Monoxide Protection
Console Test
Sensors Test
"Q201: Exit delay, in seconds (45-120)"
"Q116: Allow quick exit"
"Q201: Exit delay, in seconds (45-120)"
"Q115: Exit delay restart"
See the User Guide for the 2GIG EDGE Panel
"Q114: Auto stay"
"Q202: Entry delay 1, in seconds (30-240)"
"Q203: Entry delay 2, in seconds (30-240)"
"Q101: Enter installer code (4 or 6 digits)"
See the User Guide for the 2GIG EDGE Panel
"Q121: Keyfob/remote arming mode on system not ready"
See the User Guide for the 2GIG EDGE Panel
"Q119: Alert on disarm with keyfob after alarm"
"Q120: Keyfob arm/disarm confirmation"
"Q119: Alert on disarm with keyfob after alarm"
"Q120: Keyfob arm/disarm confirmation"
"Q205: Alarm abort window transmission delay"
"Q502: Periodic test, in days (0-255)"
"Q502: Periodic test, in days (0-255)"
"Q205: Alarm abort window transmission delay"
See the User Guide for the 2GIG EDGE Panel
"Q204: Alarm cancel time, in minutes (5-255)"
"Covert Distress Signal"
"User Duress Pin"
See the User Guide for the 2GIG EDGE Panel
"Q123: Cross sensor zones 99-100"
"Q209: Cross sensor timeout, in seconds (10-120)"
"Q208: Swinger shutdown count (1-6)"
"Q517: Alarm restore reports to CS"
"Sensor Type — 24-Hour Fire"
"Sensor Type — 24-Hour Fire Verification"
"Testing the System"