Choose one of these options:
»
Disabled: Turns the feature OFF. The system arms itself in Away Mode at the end of the Exit Delay countdown.
»
† ‡ Enabled: Turns the feature ON. The system monitors the Exit Delay door when the system is armed and if no one exits the door
before the Exit Delay countdown expires, the system automatically arms the system in Stay Mode. For compliance with ANSI/SIA CP-01-
2010, this feature is enabled by default.

Q115: Exit delay restart

Configures the system to restart the Exit Delay countdown if a user must re-enter the premises through an Exit Delay door during the initial Exit
Delay countdown. This feature can be assigned individually for each Smart Area. (Smart Areas feature must be enabled (Q107) for settings for S2-
S4 to affect the system) This is useful when a user arms the system, exits the premises, and then needs to quickly enter/exit the premises before
the countdown expires. As long as the user exits the premises during the Exit Delay Restart countdown, there is no need to disarm and re-arm the
system. When this feature is turned ON, the Exit Delay timer will restart one (1) time.
Choose one of these options:
»
† ‡ Enabled: Turns the feature ON. If the user exits and then re-enters the premises before the Exit Delay countdown expires, the Exit
Delay countdown restarts before the system is armed. For compliance with ANSI/SIA CP-01-2010, this feature is enabled by default
»
Disabled: Turns the feature OFF.
NOTE: When the Exit Delay Restart feature is enabled on the system and the user arms the system with the Silent Exit feature enabled,
the system will restart the exit countdown using the Silent Exit timer, instead of the Exit Delay timer.
NOTE: When the Exit Delay Restart feature is enabled on the system and the user triggers the Exit Delay Restart feature, the Quick Exit
button is disabled.

Q116: Allow quick exit

Configures the system to allow users to quickly exit the premises while the system is armed in Stay Mode. When this feature is turned ON and
a user taps Arm Stay, a Quick Exit button appears on the System Armed screen. When a user taps Quick Exit , the system starts the Exit Delay
countdown and the user must exit the premises before the countdown expires. After the countdown expires, the system automatically re-arms
itself in the specified arming mode.
Choose one of these options:
»
† Enabled: Turns the feature ON. This enables the Quick Exit button on the System Armed screen.
»
Disabled: Turns the feature OFF.
NOTE: The Quick Exit button is not available on the System Armed screen when the user invokes the Exit Delay Restart feature. See
Q115: Exit delay restart

Q117: Quick bypass

Configures the system to allow users to bypass a sensor without prompting the user to enter a user code. This feature can be assigned
individually for each Smart Area. (Smart Areas feature must be enabled (Q107) for settings for S2-S4 to affect the system) Typically, this feature
is disabled, so a user must enter a valid user code before bypassing a sensor.
Choose one of these options:
»
Enabled: Turns the feature ON.
»
† Disabled: Turns the feature OFF.

Q118: Auto unbypass for manual bypass

Manually bypassed sensors can have their bypass automatically removed at disarming or have their bypasses remain in place.
You have these options:
»
† Enabled: Turns the feature ON. The system automatically removes bypasses from manually bypassed sensors when the system is
disarmed.
»
Disabled: Turns the feature OFF. Manually bypassed sensors will remain bypassed when the system is disarmed.

Q119: Alert on disarm with keyfob after alarm

Configures the system to activate a unique sound when the system in the alarm state is disarmed by a keyfob. The unique sound is four (4) beeps
from the speakers on the 2GIG EDGE Panel and four (4) chirps from an external alarm sounder (if installed).
Choose one of these options:
»
Enabled: Turns the feature ON. The system emits the unique sound.
»
† Disabled: Turns the feature OFF.