Q103: Lock installer programming

This feature prevents system takeovers by locking the installer programming features in the System Configuration menu after 48 hours. The 48-hour
lockout timer starts when the installer exits System Configuration mode. To restore access after the 48-hour period, installers must reset the lockout timer
using the backend dealer portal. When this feature is enabled, the following programming features are locked out after 48 hours:
»
Q101: Enter installer code (4 or 6 digits)
»
Q103: Lock installer programming
»

Q104: Lock default programming

Choose one of these options:
»
† Disabled (Full Access): This turns the feature OFF. Installer programming remains unlocked after 48-hours.
»
No Access: This turns the feature ON. The programming features are fully restricted after 48-hours.
»
Limited Access: This turns the feature ON. The programming features are partially restricted after 48-hours.
Q104: Lock default programming
Prevents system takeovers by limiting the installer's ability to restore the factory default settings of the 2GIG EDGE Panel.
Choose one of these options:
»
† Allow Reset of All Defaults: Lets installers restore the factory-default values to the 2GIG EDGE Panel.
»
Allow Limited Reset of Defaults: Lets installers restore some of the factory-default values, with the exception of
installer code (4 or 6 digits)
48 hours after the setting is changed, and the countdown timer starts when you exit the System Configuration menu.
»
Do Not Allow Reset of Defaults: Does not let installers restore the factory default values to the 2GIG EDGE Panel. This setting
starts when you exit the System Configuration menu.

Q105: 2-way voice

Configures the system to automatically turn the 2-Way Voice feature ON or OFF after the type of alarm you specify. This gives the Cellular Radio
Module in the 2GIG EDGE Panel the ability to automatically dial the Central Station and connect with an operator after an alarm sounds. Once
connected with the Central Station, people on the premises can communicate with the operator using the built-in speaker and microphone.
Choose one of these options (next page):
»
Disabled: Disable 2-way voice.
»
† Stay on line: Default. 2-way voice is enabled.
»
Stay on line, incl fire & CO alarms: 2-way voice is enabled and includes fire and CO alarms.

Q106: Disable siren after two-way audio

Configures the system to automatically turn the alarm siren ON or OFF after the end of a 2-Way Voice session. For this setting to take effect,
"Q105: 2-way voice" above must be enabled.
Choose one of these options:
»
Enabled: Choose this setting if you want the alarm siren to remain OFF after a 2-Way Voice session ends.
»
† Disabled: Choose this setting if you want the alarm siren to resume after a 2-Way Voice session ends.
NOTE: When set to disabled, the alarm siren will only resume after a 2-way voice session when the corresponding alarm bell cutoff time
has not expired. See

Q107: Smart Areas

Configures "Smart Areas" (partitioning) feature allowing the system to be divided into four separate areas. Once enabled, zones, keyfobs, keypads,
and users can be assigned to Smart Areas allowing individual control of each area.
Choose one of these options:
»
Enabled: Smart Areas button will be displayed on 2GIG EDGE Panel and all 2GIG EDGE Remote keypads. Zones, Keyfobs, Keypads can
be assigned to a single Smart Area. Users can be assigned and control assigned Smart Areas. Smart Areas Settings will allow naming of
all four areas.
»
† Disabled: Smart Areas button will not be displayed on the home screen of the 2GIG EDGE Panel and Remote Keypads. Smart Areas
Settings will only display the main system.
NOTE: Programming of Zones, Keyfobs, and Keypads is not restricted and all devices can be programmed and assigned to any of the
four Smart Areas but will be inactive if assigned to Smart Area 2-4 until this feature is enabled.
Installation Guide for the 2GIG EDGE Security Panel
above,
Q103: Lock installer programming
Q206: Burglary bell cutoff time
above,
Q104: Lock default programming
and
.
Q207: Fire bell cutoff time
44
Q101: Enter
above. This setting takes effect