Q509: Ac Loss Reports To Cs; Q510: Ac Restore Reports To Cs; Q511: System Low Battery Reports To Cs; Q512: System Low Battery Restore Reports To Cs - 2gig Technologies EDGE Installation Manual

Security & smart home system
Hide thumbs Also See for EDGE:
Table of Contents

Advertisement

Q509: AC loss reports to CS

Configures the system to transmit reports to the Central Station if the 2GIG EDGE Panel loses AC power. When enabled, this setting waits the
number of minutes specified in
Q210: Time to detect AC loss, in minutes
be sent at a random time of up to 45 minutes after the power loss event.
»
† Enabled: The system transmits a report to the Central Station.
»
Disabled: The system does not transmit a report to the Central Station.
When the system loses AC power, a
"Power Lost"
message appears on the touchscreen and the system icon state changes to show that the 2GIG
EDGE panel is not operating on AC power.

Q510: AC restore reports to CS

Configures the system to transmit a report to the Central Station when AC power is restored to the 2GIG EDGE Panel. When enabled, AC power
must be restored for one (1) minute before the trouble condition clears from the system.
You have these options:
»
† Enabled: The system transmits a report to the Central Station. If
sent at a random time up to 45 minutes after the trouble conditions clears.
»
Disabled: The system does not transmit a report to the Central Station.

Q511: System low battery reports to CS

Configures the system to transmit low battery reports about the 2GIG EDGE Panel to the Central Station.
Choose one of these options:
»
† Enabled: The system transmits a report to the Central Station.
»
Disabled: The system does not transmit a report to the Central Station.

Q512: System low battery restore reports to CS

Configures the system to transmit a report to the Central Station after a low battery condition on the 2GIG EDGE Panel is restored.
Choose one of these options:
»
† Enabled: The system transmits a report to the Central Station.
»
Disabled: The system does not transmit a report to the Central Station.

Q513: RF low battery reports to CS

Configures the system to transmit low battery reports about the system's sensors and peripherals to the Central Station.
Choose one of these options:
»
† Enabled: The system transmits a report to the Central Station.
»
Disabled: The system does not transmit a report to the Central Station.

Q514: Sensor low battery restore reports to CS

Configures the system to transmit a report to the Central Station after a low battery condition for a sensor is restored.
Choose one of these options:
»
† Enabled: The system transmits a report to the Central Station.
»
Disabled: The system does not transmit a report to the Central Station.

Q515: System disarmed reports to CS

Configures the system to transmit a report to the Central Station when the system is disarmed by a user. The report includes the keyfob or user
code that disarmed the system.
Choose one of these options:
»
Enabled: The system transmits a report to the Central Station.
»
† Disabled: The system does not transmit a report to the Central Station.
NOTE: Arming setting on Alarm.com monitoring settings supersedes Q515: System disarmed reports to CS

Q516: System armed reports to CS

Configures the system to transmit a report to the Central Station when the system is disarmed by a user. The report includes the keyfob or user
code that disarmed the system.
Choose one of these options:
»
Enabled: The system transmits a report to the Central Station.
»
† Disabled: The system does not transmit a report to the Central Station.
NOTE: Arming setting on Alarm.com monitoring settings supersedes Q516: System armed reports to CS
2GIG EDGE Installation Guide
,
page
49. If
Q211: Random AC loss report time
above is enabled, the report will
above is enabled, the report will be
Q211: Random AC loss report time
54

Q517: Alarm restore reports to CS

Configures the system to transmit reports to the Central Station after an alarm, either when the Bell Cutoff Time expires or when the system is
disarmed.
You have these options:
»
Enabled: The system transmits a report to the Central Station. Depending on the number of trips set for a cross sensor zone, the
feature works as follows:
»
If enabled and
on page 1 is set to two (2) trips, the system transmits a report when the triggering sensor is closed (i.e., in its
Q208
normal state) at the Bell Cutoff Time or if the sensor is closed after the Bell Cutoff Time.
»
If enabled and
Q208
on page 1 is set to one (1) trip, the system transmits a report only if the sensor is closed at the time the system is
disarmed. Reports are not sent if a sensor is in swinger shutdown until the time of disarm and the sensor is closed.
»
† Disabled: The system does not transmit a report to the Central Station.
NOTE: Alarms setting on Alarm.com monitoring settings supersedes Q517: Alarm restore reports to CS.

Q518: Smart test reports

Configures the system to transmit smart test reports to the Central Station. A smart test report is designed to reduce incoming network traffic for
the Central Station. When enabled in combination with
Q502: Periodic test, in days (0-255)
will restart the periodic test report timer (for example, alarm, restore, trouble, etc.). Periodic test reports are only sent when the 2GIG EDGE Panel
has not reported in any way to the Central Station.
Choose one of these options:
»
Enabled: The system transmits a report to the Central Station.
»
† Disabled: The system does not transmit a report to the Central Station.

Restore the Factory Default Settings

You can restore the Control Panel settings back to their factory defaults.
A soft reset lets you select which settings to restore back to the factory defaults.
To perform a soft reset:
1 . Navigate to the Installer Toolbox options.
2 . Tap RESTORE DEFAULTS.
3 . At the Restore Defaults screen, tap the switch adjacent to areas that you would like to restore and tap RESTORE.
Restore Defaults Screen
This restores the factory defaults setting for the areas selected, and then the system restarts.

2GIG EDGE REMOTE KEYPAD

The Remote Keypad (2GIG-EDG-RK) is a wall-mounted, full-color, touch screen interface that provides all of the same easy-to-use keypad
functions available on the Control Panel. It is designed for indoor use only and gives users the ability to arm and disarm the system, see the status
of sensor zones, and control Smart Home devices.
For installation and pairing instructions, refer to the 2GIG EDGE Remote Keypad manual.
, all non-test reports occurring during normal operations