Q305: Temperature display units

Specifies the temperature scale used by the system to display weather forecasts on the touchscreen.
NOTE: Weather forecasts are only available on the 2GIG EDGE Panel when enabled by the service provider.
Choose one of these options:
† Fahrenheit: Displays information using the Fahrenheit temperature scale.
Celsius: Displays information using the Celsius temperature scale.

Q306: Configuration change acknowledgement

Configures the system to annunciate or suppress annunciation of the panels status after a reboot or panel programming.
»
† Enabled: The panel will announce the panel status when the panel powers up, reboots, or exits programming.
»
Disabled: This option will suppress the annunciation of the panel status when the panel powers up, reboots, or exits programming.
NOTE: When any changes are made to the panel from Alarm.com, including programming questions, changes to sensors, adding,
deleting, or changing users, the 2GIG EDGE panel will announce its status. Example: "System disarmed, ready to arm." Changing Q306
to Disabled will suppress this annunciation from the panel.
NOTE: Q306 will only affect the annunciation of the status of the panel, as described above. Q306 will not affect any other annunciations
of the 2GIG EDGE panel.

Q307: Open collector #1 output

Defines output mode for the external device connected to the OCL1 position of the panel's terminal block. See Control Panel Wiring Diagram,
page 24.
NOTE: For compliance with ANSI/SIA CP-01-2010, you must set Open Collector Output #1 to 11 - Follows Internal Sounder Alarm.
NOTE: If you enabled a keyfob auxiliary button to trigger the panel's Open Collector #1, make sure this question is set to 00 Disabled,
"Program a Keyfob."
Choose one of these options:
Code
Open Collector Output
00
Disabled
01
Activated When Armed
02
Activated When Disarmed
03
Activated on FTC (Failure to Communicate
04
Activated on Siren Supervision
05
Activated on Radio Fault

Q308: Open collector #2 output

Defines the output mode for the external device connected to the OCL2 position of the panel's terminal block. See Control Panel Wiring Diagram,
page 24.
NOTE: The factory default setting for
Choose one option from
Open Collector Output Table

Q309: Allow backlight always on

Configures the system to always display the option to leave the touchscreen's backlight on. This is useful when users want to demonstrate panel
features, without the system backlight timing out.
IMPORTANT: Leaving the backlight ON for extended periods of time may result in image retention. To avoid this, it is recommended that
you only enable this feature when the panel is intended for use as a demonstration system.
Choose one of these options:
»
Enabled: The backlight for the touchscreen is always ON.
»
† Disabled: The backlight for the touchscreen dims automatically after 60 seconds of inactivity.
NOTE: Timeout has to be set in Screen Settings in order for this option to take affect.
Code
Open Collector Output
06
Activated on Burglary Alarm
07
Activated on Fire Alarm
08
Activated on Any Alarm
09
Activated on Any System Trouble
† 11
Follows Internal Sounder Alarm
12
Follows Exit/Entry Beeps
Open Collector Output #2 is 00-Disabled
(above).