Q405: Broadband network failure causes trouble

Configures the system to display a trouble alert on the touchscreen when it logs a trouble alert condition with the broadband network connection.
The 2GIG EDGE Panel will display an alert message on the touchscreen after the number of minutes specified in
time, in minutes (0-255)
above expires.
Choose one of these options:
»
† Enabled: Turns the feature ON. The 2GIG EDGE Panel displays a visual trouble indicator after the broadband network failure.
»
Disabled: Turns the feature OFF. The 2GIG EDGE Panel will not display a visual indicator after a broadband network failure. Once the
network connection is restored, the system automatically clears the visual indicator. A record of the trouble alert condition is stored in the
System History.

Q406: Broadband network failure reports

Configures the system to transmit a trouble report to the Central Station when the system detects a broadband network connection.
Choose one of these options:
»
† Enabled: Turns the reporting feature ON. The 2GIG EDGE Panel will transmit a trouble report to the Central Station after a broadband
network failure.
»
Disabled: Turns the reporting feature OFF. The 2GIG EDGE Panel will not transmit a trouble report to the Central Station after a
broadband network failure.

Q407: Trouble doesn't sound at night

Prevents audible trouble alerts from waking users during nighttime hours. When this feature is turned ON, audible trouble alerts are suppressed
between the pre-configured hours of 10:00 PM - 9:00 AM. This setting does not suppress any other trouble alert features. The system will
continue to display trouble alert messages on the touchscreen.
It will also continue to transmit trouble reports to the Central Station, as well as to log trouble alerts in the system's Alarm History.
If the reported trouble condition clears on its own or a user acknowledges the condition(s) on the Control Panel before 9:00 AM, no trouble tones
will sound after 9:00 AM. However, the trouble condition is recorded in the system's Alarm History.
Choose one of these options:
»
† Enabled: Turns the feature ON.
»
‡ Disabled: Turns the feature OFF. For compliance with UL 985: Household Fire Warning System Units, this setting must be disabled.

Q408: RF jam causes trouble

Configures the system to activate a trouble condition when the 2GIG EDGE Panel's wireless receiver detects that one of the system's RF
transmitters is causing an RF jam. For this setting to go into affect, you must also enable
Choose one of these options:
»
Enabled: The system detects RF jamming.
»
† Disabled: The system does not detect RF jamming.

Q409: System tamper causes trouble

Configures the system to activate a trouble condition if one of the 2GIG EDGE Panel's tamper switches (wall tamper switch or cell radio tamper
switch) is triggered while the system is disarmed. The system will also activate an alarm condition if a tamper switch is triggered while the
system is armed.
You have these options:
»
† Enabled: The system activates a trouble condition.
»
Disabled: The system does not activate a trouble condition.
CS Reporting

Q501: CS lack of usage notification time, in days

Configures the system to monitor itself for lack of usage. If the system is not armed for the number of days you specify here, an inactivity report is
sent to the Central Station.
Choose one of these options:
»
0 Days: Turns this feature OFF.
»
1-255 Days: Turns this feature ON and transmits an inactivity report to the Central Station after the specified number of days.
»
† 7 Days: Turns this feature ON and transmits an inactivity report to the Central Station after seven (7) days of inactivity.
2GIG EDGE Installation Guide
Q404: Broadband network failure

Q504: Trouble reports to CS

.
52

Q502: Periodic test, in days

Configures the system to automatically transmit periodic test reports about the 2GIG EDGE Panel's connections to the Central Station at the
recurring interval you specify here.
Choose one of these options:
»
0 Days: Turns the feature OFF. The system does not transmit periodic test reports to the Central Station.
»
1-255 Days: Turns the feature ON. The system transmits periodic test reports to the Central Station at recurring intervals using the
number of days specified here.
»
† 30 Days: Turns the feature ON. The system transmits periodic test reports to the Central Station once every 30 days.

Q503: Programming mode entry reports to CS

Configures the system to transmit programming reports to the Central Station. When enabled, this setting automatically transmits a report to the
Central Station when programming mode is started and terminated.
Choose one of these options:
»
Enabled: The system transmits a report to the Central Station.
»
† Disabled: The system does not transmit a report to the Central Station.
NOTE: Programming access setting on Alarm.com monitoring settings supersedes Q503 Programming mode entry reports to CS.
Q504: Trouble reports to CS
Configures the system to transmit trouble reports to the Central Station when the system detects that any sensor encounters a trouble condition.
NOTE: This setting does not affect trouble reports caused by Control Panel conditions. It only affects trouble reports caused by sensors.
»
† Enabled: The system transmits a report to the Central Station.
»
Disabled: The system does not transmit a report to the Central Station.
NOTE: Trouble setting on Alarm.com monitoring settings supersedes Q504: Trouble reports to CS.

Q505: Trouble restore reports to CS

Configures the system to transmit reports to the Central Station when a sensor's trouble condition clears.
Choose one of these options:
»
† Enabled: The system transmits a report to the Central Station.
»
Disabled: The system does not transmit a report to the Central Station.
NOTE: Trouble restore setting on Alarm.com monitoring settings supersedes Q505: Trouble restore reports to CS.

Q506: Manual bypass reports to CS

Configures the system to transmit reports to the Central Station whenever a sensor is manually bypassed by a user.
»
Enabled: The system transmits a report to the Central Station.
»
† Disabled: The system does not transmit a report to the Central Station.
NOTE: Bypass setting on Alarm.com monitoring settings supersedes Q506: Manual bypass reports to CS.

Q507: Bypass restore reports to CS

Configures the system to transmit reports to the Central Station when a bypassed sensor (forced or manually bypassed) is restored.
Choose one of these options:
»
Enabled: The system transmits a report to the Central Station.
»
† Disabled: The system does not transmit a report to the Central Station.
NOTE: Bypass setting on Alarm.com monitoring settings supersedes Q507: Bypass restore reports to CS

Q508: Force bypass reports

Configures the system to transmit a report to the Central Station when a user force-bypasses a sensor while the system is armed.
You have these options:
»
Enabled: The system transmits a report to the Central Station.
»
† Disabled: The system does not transmit a report to the Central Station.
NOTE: Forced bypassed sensors are always recorded in the event log, regardless of the setting of this programming question. Bypass
setting on Alarm.com monitoring settings supersedes Q508: Force bypass reports to CS.