Table A-3
Environmental Ranges
Operating temperature
Storage temperature
Operating altitude
Storage altitude
Thermal spacing
Power Requirements
AC input voltages
Maximum AC power input
current
DC input voltages
Maximum DC input current
Physical Dimensions
Weight
Dimensions (W x D x H)
Table A-4
Hazardous Locations
IECEx TR
ATEX
North American divisions
North American zones
InMETRO
OL-13017-01
Technical Specifications for the Power Converter
–29 to 165°F (–34 to 74°C)
–40 to 185°F (–40 to 85°C)
Up to 13,000 ft (3962 m)
Up to 40,000 ft (12,192 m)
3.54 in. (90 mm) exposed side
4.13 in. (105 mm) top and bottom
Range: 85–264 VAC at 47–63 Hz
Nominal: 115 VAC at 60 Hz or 230 VAC at 50 Hz
0.75 A @ 230 VAC and 50 Hz or
1.3 A @ 115 VAC and 60 Hz
Range: 88–375 VDC
Nominal: 125 VDC or 250 VDC
0.75 A at 220 VDC or
1.25 A at 150 VDC
1.4 lb (0.63 kg)
2 x 4.62 x 5.81 in. (50.8 x 117.5 x 147.6 mm)
Note
Hazardous Locations Standards
Standards
IEC 60079-15: 2005, third edition
IEC 60079-0: 2004, fourth edition
EN 60079-15: 2005
EN 60079-0: 2006
ANSI/ISA 12.12.01-2007
CSA C22.2 no. 213-M1987
UL 60079-15, first edition
CAN/CSA E 60079-15: 02
IEC 60079-15: 2001
IEC 60079-0: 2000
Width includes the cosmetic end-caps. Height does not
include the panel mount brackets. Depth is the distance
from the rail.