Verifying Switch Operation

Wiring the DC Power Source

Read these warnings before wiring the DC power source:
This product is intended to be supplied by a Listed Class 2 power source marked with "Class 2" and rated
Caution
from 18 to 60 VDC, 2.1 A.
A readily accessible two-poled disconnect device must be incorporated in the fixed wiring.
Warning
Statement 1022
This product relies on the building's installation for short-circuit (overcurrent) protection. Ensure that
Warning
the protective device is rated not greater than:
5A. Statement 1005
Warning
Installation of the equipment must comply with local and national electrical codes. Statement 1074
Warning
Before performing any of the following procedures, ensure that power is removed from the DC circuit.
Statement 1003
Warning
Only trained and qualified personnel should be allowed to install, replace, or service this equipment.
Statement 1030
You must connect the switch only to a DC-input power source that has an input supply voltage from 18
Caution
to 60 VDC. If the supply voltage is not in this range, the switch might not operate properly or might be
damaged.
For wire connections to the power and relay connector, you must use UL- and CSA-rated, style 1007 or
Caution
1569 twisted-pair copper appliance wiring material (AWM) wire (such as Belden part number 9318).
To wire the switch to the optional AC/DC converter, go to the
Converter" section on page
Cisco IE 3000 Switch Hardware Installation Guide
2-16
2-44.
Chapter 2
Switch Installation
"Connecting the Switch to the Power