7.4.3.8

Home CHM Test

The following actions occur during the Home CHM test:
CHM moves in and out on the short axis
CHM moves on the long axis
Gripper of the CHM closes and opens
1. Select the Maintenance Menu by pressing
2. Select the Diagnostics Menu by pressing
3. Select Home CHM by pressing
To abort this diagnostic, press Escape and Enter.
7.4.3.9

Cycle Pick/Place Test

The Cycle Pick/Place test picks a cartridge from the element you specify and
places it back in the same element. You can specify the number of times you want
this test repeated.
1. Select the Maintenance Menu by pressing
2. Select the Diagnostics Menu by pressing
3. Select Cycle Pick/Place by pressing
The system displays the following screen:
Set Source
↑ Increase
↓ Decrease
4. Select the element index of the cartridge slot from which you want the CHM to
pick and place the cartridge by pressing
The system displays this screen:
Set Cycles
↑ Increase
↓ Decrease
5. Select the number of cycles (in increments of ten) you want the Cycle Pick/
Place to run by pressing
The test picks a cartridge from the element you specify and places it back in the
same element.
7-20
Sun StorEdge L400 Installation and User's Guide • April 1998
or
or
or
, then Enter.
or
or
or
, then Enter.
0
or
10
or
, then Enter.
↑,
then Enter.
, then Enter.
, then Enter.
, then Enter.
, then Enter.