Care, maintenance and disposal

General remarks
Under normal operating conditions the auto-transformer requires only a minimum of care
and maintenance. However, it is vital to observe some important points to ensure the
welding machine remains in a usable condition for many years.
-
At every start-up
-
Every 6 months
-
-
Dispose of in accordance with the applicable national and local regulations.
Disposal
Warning! An electric shock can be fatal. Before opening the machine
-
switch the mains switch to the "O" position
-
unplug machine from the mains
-
put up an easy-to-understand warning sign to stop anybody inadvertently
switching it back on again
Check mains cable for damage
Check that there is a gap of 0.5 m (1.6 ft.) all around the machine to ensure that
cooling air can flow and escape unhindered.
Note: Air inlets and outlets must never be covered, not even partially.
Caution! Inadequate PE conductor connections can cause serious injury and
damage. Before re-fitting the housing cover, ensure correct connection of the
PE conductor.
Remove the housing cover and clean the interior of the machine with dry, reduced
compressed air
Note: Risk of damage to electronic components. Do not bring the air nozzle too
close to the electronic components.
If a lot of dust has accumulated, clean the cooling-air ducts.