The following tables provide power consumption information for the EX1200 series plug-in
modules. The EX1200 mainframe power is also provided to assist in determining available power.
Switch Module
EX1200-2001
EX1200-2002
EX1200-2007A
EX1200-2008H
EX1200-3001
EX1200-3048
EX1200-3048S
EX1200-3072
EX1200-3096
EX1200-3164
EX1200-4003
EX1200-4128
EX1200-4260
EX1200-4264
EX1200-5001
EX1200-5002
EX1200-5006
EX1200-6101
EX1200-6111
EX1200-6216
EX1200-6216HV
EX1200-7100
7102 plug-in
7104 plug-in
7106 plug-in
7122 plug-in
Switch Module
EX1200-1538
EX1200-3604
EX1200-3608
EX1200-7416
EX1200-7500
EX1200-7600
Appendix B
C
ONSUMPTION
+3.3 V
+5 V
0.131 A
0.0037 A*
0.131 A
0.0037 A*
0.135 A
0.0041 A*
0.140 A
0.005 A*
0.135 A
0.0041 A*
0.129 A
0.0041 A*
0.131 A
0.0041 A
0.129 A
0.0041 A*
0.140 A
0.005 A*
0.129 A
0.0041 A*
0.137 A
0.0040 A*
0.129 A
0.0041 A*
0.014 A
0.005 A*
0.014 A
0.005 A*
0.129 A
0.0041 A*
0.129 A
0.0041 A*
0.140 A
0.005 A*
0.140 A
0.005 A*
0.140 A
0.005 A*
0.129 A
0.0041 A*
0.140 A
0.005 A*
0.131 A
0.0037 A
0.131 A
0.0037 A
0.131 A
0.0037 A
0.131 A
0.0037 A
0.131 A
0.0037 A
+3.3 V
+5 V
0.380 A
0.0081 A
0.3 A
1.0 A
0.3 A
1.0 A
0.250 A
0.0051 A*
0.260 A
0.450 A
0.129 A
0.0041 A*
A
PPENDIX
+24 V
Notes
0 A
*Add 75 mA per relay closure on 5 V
0 A
*Add 75 mA per relay closure on 5 V
0 A
*Add 40 mA per relay closure on 5 V
0 A
*Add 17 mA per relay closure on 5 V
0 A
*Add 26 mA per relay closure on 5 V
0 A
*Add 23 mA per relay closure on 5 V
0 A
N/A
0 A
*Add 23 mA per relay closure on 5 V
0 A
*Add 28 mA per relay closure on 5 V
0 A
*Add 23 mA per relay closure on 5 V
0 A
*Add 25 mA per relay closure on 5 V
0 A
*Add 28 mA per relay closure on 5 V
0 A
*Add 28 mA per relay closure on 5 V
0 A
*Add 28 mA per relay closure on 5 V
0 A
*Add 23 mA per relay closure on 5 V
0 A
*Add 23 mA per relay closure on 5 V
0 A
*Add 28 mA per relay closure on 5 V
0 A
*Add 28 mA per relay closure on 5 V
0 A
*Add 28 mA per relay closure on 5 V
0 A
*Add 28 mA per relay closure on 5 V
0 A
*Add 67 mA per relay closure on 5 V
0 A
Values for carrier only
0.005A*
*Add 140 mA per relay closure on 24 V
0.005A*
*Add 140 mA per relay closure on 24 V
0.005A*
*Add 140 mA per relay closure on 24 V
0.005A*
*Add 280 mA per relay closure on 24 V
+24 V
Notes
0.15 A
N/A
0.8 A
N/A
1.4 A
N/A
0.133 A
*Add 24 mA per relay closure on 5 V
(two relays per channel used)
0.0240 A
N/A
0.2 A**
*Add 24 mA per relay closure on 5 V
** Maximum value
www.vtiinstruments.com
B
153

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Metek EX1202 and is the answer not in the manual?

Subscribe to Our Youtube Channel

Table of Contents