Measurement Example; Performing External Rf Power Measurements; Connecting A Cable - JDS Uniphase CellAdvisor JD780A Series User Manual

Table of Contents

Advertisement

JD780A Series Analyzers

Measurement example

Figure 292 Internal power measurement

Performing external RF power measurements

This instrument performs radio output power measurement with the use of optional external power
sensors including JD730 series power sensors. It serves as the highly accurate RF power meter and
gives wider range of power measurement.

Connecting a cable

There are two types of power sensors. Directional power sensors are used in in-service power
measurement. Terminating power sensors are used in out-of-service power measurement.
Table 23
External power sensor type
Part No.
Description
JD731B
Directional Power Sensor
JD732B
Terminating Power Sensor
JD733A
Directional Power Sensor
JD734B
Terminating Power Sensor
JD736B
Terminating Power Sensor
Terminating power sensor connection
Procedure
1.
Connect an external power sensor to the USB Host port of the JD780A series and to the RF
554
Frequency Range
300-3800 MHz
20-3800 MHz
150-3500 MHz
20-3800 MHz
20-3800 MHz
Using Power Meter
Power Range
Average: +21.76 to +51.76 dBm
(0.15 to 150 W)
Peak: +36.02 to +56.02 dBm
(4 to 400 W)
Average: -30 to +20 dBm
Average/Peak: +20 to +47 dBm
(0.1 to 50 W)
Peak: -30 to +20 dBm
Average/Peak: -30 to +20 dBm

Advertisement

Table of Contents
loading

This manual is also suitable for:

Celladvisor jd785aCelladvisor jd786aCelladvisor jd788a

Table of Contents