Measurement example
Figure 173 Code domain power measurement with CDMA OTA signal analyzer
NOTE
You can use the LIMIT hot key to analyze your measurements with the user-definable
limit and Pass/Fail indication.
Setting display
You can view .your measurement results in a different view option.
Procedure
1.
Press the TRACE/DISPLAY hard key.
2.
Press the Code Order soft key, and then select the code order option from the following choices:
Hadamard: To assign the number based on Walsh code order and display the measured
code power according to the assigned number in sequence.
Bit Reverse: Code number in binary bit is reversed relative to the Hadamard method.
3.
Toggle the Base Code Length soft key and select the base Walsh code number: 64 or 128.

Route map

The JD780A Series provides the Route Map function that allows you to collect data of points in an
indoor or outdoor environment and track the received signals and coverage of RF transmitters by
plotting data real time directly on top of a loaded floor plan or a map.
Setting measure setup
Procedure
1.
If required, connect a GPS receiver to your JD780A series for outdoor mapping.
Indoor mapping does not necessarily need a GPS antenna.
Configure test parameters as described in the "Configuring test parameters" on page 334.
2.
Using CDMA Signal Analyzer
JD780A Series Analyzers