Measurement Example; Conducting Wcdma/Hspa+ Ota Measurements; Channel Scanner - JDS Uniphase CellAdvisor JD780A Series User Manual

Table of Contents

Advertisement

Procedure
1.
Press the MEASURE SETUP hot key.
2.
Press the CCDF Length soft key to set the length of the CCDF.
3.
Enter a value between 1 and 100 by using the numeric keys. You can also use the rotary knob.
4.
Press the Enter soft key.

Measurement example

Figure 70
CCDF measurement with WCDMA/HSPA+ signal analyzer

Conducting WCDMA/HSPA+ OTA measurements

This Over The Air (OTA) measurement has channel scanner, scramble scanner, multipath profile, code
domain power, and route map screens. Scramble scanner displays six scrambling codes and powers
to inform neighbor cells existence and its power. The multipath profile graph helps you to determine
testing area's RF environmental condition. The code domain power shows not only modulation
performance metric but also amplifier capacity and code utilization metric. The amplifier capacity (code
utilization) measurement is an estimate of the amount of power amplifier capacity (code utilization) that
is being used expressed in percent of maximum.

Channel scanner

Setting channel/frequency
Procedure
To set the channels to be scanned:
1.
Press the FREQ/DIST hard key.
2.
Toggle the Unit soft key and select Channel.
3.
Press the Index soft key, and then enter an index number by turning the rotary knob or using the
numeric keys.