Multipath Profile - JDS Uniphase CellAdvisor JD780A Series User Manual

Table of Contents

Advertisement

JD780A Series Analyzers
Measurement example
Figure 108 ID scanner measurement with LTE - FDD OTA signal analyzer

Multipath profile

The Multipath Profile enables you to determine RF environmental conditions of testing area. It
indicates the amount of power of the dominant pilot signal that is dispersed outside the main
correlation peak due to multipath echoes that are expressed in dB. This value should be very small
ideally.
The multipath profile is the result of portions of the original broadcast signal arriving at the receiving
antenna out of phase. This can be caused by the signal being reflected off objects such as buildings,
or being refracted through the atmosphere differently from the main signal.
Setting measure setup
After configuring test parameters as described in the "Configuring test parameters" on page 197, you
can continue your measurement.
Procedure
1.
Press the MEASURE SETUP hot key.
2.
To set the nominal channel bandwidth to be measured, complete the following steps:
a.
Press the Bandwidth soft key.
b.
Select the bandwidth option: 1.4 MHz, 3 MHz, 5 MHz, 10 MHz, 15 MHz, or 20 MHz.
3.
Toggle the Display soft key and select RS or Sync.
The RS Window soft key becomes activated if RS is selected.
4.
Press the RS Window soft key, if RS is selected, and then select the RS window option: 2 µs,
4 µs, or 8 µs.
5.
Optional. Press the Miscellaneous soft key, and then do the following(s) as needed:
To select the number of antenna ports, toggle the MIMO soft key and select 2x2 or 4x4.
This MIMO (Multiple Input Multiple Output) setting is activated only if the option 030 LTE-
Advanced FDD is installed with a license number. If not, the instrument sets this option to
246
Using LTE - FDD Signal Analyzer

Advertisement

Table of Contents
loading

This manual is also suitable for:

Celladvisor jd785aCelladvisor jd786aCelladvisor jd788a

Table of Contents