inverters
Goodrive200L
Fault
code
Ethernet communication
E-NET
CANopen communication
E-CAN
LL
Electronic underload fault
Running contactor
RE
feedback error
Brake contactor feedback
BE
ENC1O
Encoder wire break fault
Fault type
Fault
fault
error
Possible cause
The Ethernet address
is not set right.
The Ethernet
communication is not
selected to right.
The ambient
interference is too
strong.
Corresponding
resistor is not dial
The communication is
uneven
The inverter will report
the underload
pre-alarm according to
the set value
Running Contactor
feedback signal lost
Brake contactor
feedback signal lost
Encoder fault or wiring
fault
132
Fault tracking
What to do
Check the relative
setting.
Check the
communication
method selection.
Check the environment
and avoid the
interference.
Check related setting
Set the same baud
rate
Check the environment
and avoid the
interference.
Check the load and the
underload pre-alarm
point
Check the circuit or
disable the feedback
signal detection
Check the circuit or
disable the feedback
signal detection
Check the encoder and
the wiring
Need help?
Do you have a question about the Goodrive 200L and is the answer not in the manual?
Questions and answers