Program 80 : Basic Hardware Setup for System
Level:
MF
Description
Use Program 80-04 : Call Progress Tone Detector Setup to define the various levels and timers for
Program
the Call Progress Tone Detector.
80
Tone Detector Type :
• 1 = Dial Tone for Trunk
• 2 = Busy Tone for Trunk
• 3 = Ring Back Tone for Trunk
• 4 = Reorder Tone for Trunk
• 5 = Stutter Tone for Trunk
Input Data
Item
No.
01
Detection Level
02
Min. Detection Level
03
S/N Ratio
04
No Tone Time
05
Pulse Count
06
ON Minimum Time
07
ON Maximum Time
2-492

80-04 : Call Progress Tone Detector Setup

Tone Detector Type Number
Item
1 = Dial Tone for Trunk
2 = Busy Tone for Trunk
3 = Ring Back Tone for Trunk
4 = Reorder Tone for Trunk
5 = Stutter Tone for Trunk
Input Data
0 = 0 dBm ~ - 25 dBm
1 = - 5 dBm ~ - 30 dBm
2 = - 10 dBm ~ - 35 dBm
3 = - 15 dBm ~ - 40 dBm
4 = - 20 dBm ~ - 45 dBm
5 = - 25 dBm ~ - 50 dBm
6 = - 30 dBm ~ - 55 dBm
0 ~ 15
0 = - 10 dBm (0) ~ - 25 dBm (15)
1 = - 15 dBm (0) ~ - 30 dBm (15)
2 = - 20 dBm (0) ~ - 35 dBm (15)
3 = - 25 dBm (0) ~ - 40 dBm (15)
4 = - 30 dBm (0) ~ - 45 dBm (15)
5 = - 35 dBm (0) ~ - 50 dBm (15)
6 = - 40 dBm (0) ~ - 55 dBm (15)
0 ~ 4 (0 dB ~ - 20 dB)
0 ~ 255 (30 + 30 ~ 7680 ms)
(0 = not detect)
1 ~ 255 = 60 ~ 7680 ms
The formula is 30 + 30N
When set to N = 1, it means 30 + 30
When set to N = 255, it means 30 + 30
7680.
0 ~ 255
0 ~ 255 (30 + 30 ~ 7680 ms)
0 ~ 255 (30 + 30 ~ 7680 ms)
Program 80 : Basic Hardware Setup for System
ISSUE 2.0
Default
Refer below
Refer below
Refer below
Refer below
1 = 60.
*
*
255 =
Refer below
Refer below