NEC SL2100 Programming Manual page 610

Hide thumbs Also See for SL2100:
Table of Contents

Advertisement

SL2100
Alarm
Name
No.
29
Charge
manage-
ment buffer
full
Program
90
30
SMDR buf-
fer full
31
Sensor Au-
to Dial
32
Confirm Di-
al NoAns
33
Reserved
34
Reserved
35
Reserved
36
Reserved
37
Reserved
38
Reserved
39
Reserved
40
Reserved
41
License
Name File
Load error
42
4W termi-
nals does
not start
up.
43
2W termi-
nals does
not start
up.
44
Reserved
45
Reserved
2-586
Item
Item
Content of
No.01
No.02
alarm
de-
de-
< generation
fault
fault
timing >
0
0
The temporary
buffer for the
charge man-
agement in
main device
was overflow,
and a part of
unoutput
charge data
disappeared
because it was
not able to out-
put the charge
management
data.
<Operate it >
2
0
The temporary
buffer for
SMDR in main
device was
overflow, and a
part of unoutput
SMDR data
disappeared
because it was
not able to out-
put SMDR da-
ta.
<Operate it >
1
0
1
0
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0
Can't show Li-
cense Name,
because Sys-
tem fails to load
license name
file with system
boot up.
2
0
308U or 008U
(WW) install to
Slot-4.
2
0
082U install to
Slot-4.
2
0
0
0
Cause
Measures
1.
The charge
1.
Please print
data is printed
and delete the
and not de-
charge data at
leted at the
the simple
simple charge
charge man-
management.
agement.
2.
The charge
2.
Please con-
data is not out-
nect the
put to PC for
charge man-
the charge
agement soft-
management
ware for the
software.
charge man-
agement soft-
ware and out-
put the charge
data.
1.
Problem of wir-
1.
Please confirm
ing to connect
whether there
main device
is problem in
with PC.
wiring to con-
2.
Problem of
nect a main
PC.
device with
PC.
2.
Please exe-
cute the reacti-
vation of PC.
License Name File
Execute
is broken or file for-
PRG90-04-03 after
mat is invalid.
copy valid license
name file to SD
Card again.
308U or 008U
Especially, anything
(WW) install to
need not be done.
Slot-4.
082U install to
Especially, anything
Slot-4.
need not be done.
Program 90 : Maintenance Program
ISSUE 2.0
Alarm
Recovery
Status
When the
ERR
output is re-
REC
started, the
error is re-
covered.
However,
the charge
manage-
ment data
after the er-
ror occurs is
not recor-
ded.
When the
ERR
output is re-
REC
started, the
error is re-
covered.
However,
the SMDR
data after
the error oc-
curs is not
recorded.
INF
INF
Canceled
ERR
after valid li-
REC
cense name
file is loa-
ded.
INF
INF

Hide quick links:

Advertisement

Table of Contents
loading