NEC SL2100 Programming Manual page 607

Hide thumbs Also See for SL2100:
Table of Contents

Advertisement

ISSUE 2.0
Item
Alarm
No.01
Name
No.
de-
fault
4
PKG S/W
2
Download
Error
5
Reserved
0
6
Blocking
0
7
Power fail-
1
ure
8
Memory
1
backup
battery er-
ror
9
Reserved
0
Programming Manual
Item
Content of
No.02
alarm
de-
< generation
fault
timing >
0
The unit pro-
• The package
gram was not
software is not
able to be
stored in the
downloaded
downloaded SD
normally.
card.
The unit was
• The stored pack-
not able to be
age software is
started normal-
illegal.
ly.
• Package infor-
<The unit
mation that had
starts >
been installed
before remains.
0
0
The link of ter-
• Breakdown of
minals connec-
terminal
ted with the ESI
• Faulty wiring and
package came
wiring determina-
off.
tion
<It starts and
• External noise
operate it >
• Breakdown of
ESI package
0
The supply of
• The power cable
the commercial
came off.
power stopped.
• Power failure
<Operate it >
• The power sup-
ply unit broke
down.
0
The battery for
• The battery for
the backup of
the backup of the
the memory on
memory on the
the CPU was
CPU board was
consumed or it
consumed or it
comes off.
comes off.
<Operate it >
0
Cause
Measures
Delete slot informa-
tion that corre-
sponds by
PRG90-05-01 to
delete package in-
formation that had
been installed be-
fore.
There is a possibili-
ty that the unit pro-
gram is broken
though an external
factor of the noise
etc. is thought.
Please load into
the SD card and try
again when you
back up the unit
program. Please in-
quire of the manu-
facturer when not
restoring it.
Confirm the termi-
nal connected with
same ESI. If they
work normally, con-
firm the breakdown
or the wiring for the
terminal.
Exchange the ter-
minal that doesn't
work and the work-
ing terminal, and
confirm its working.
An external factor
of the noise etc. is
thought.
Please reconfirm
wiring and the in-
stallation, etc.
Please inquire of
the manufacturer
when the problem
occurs after it con-
firms it.
Confirm the power
supply outlet when
the commercial
power has not
stopped.
Please inquire of
the manufacturer
when the problem
occurs after it con-
firms it.
Confirm the normal
insertion of the bat-
tery. If it is no prob-
lem, change the
battery that has
consumed. The
battery longevity is
five years.
SL2100
Alarm
Recovery
Status
Please ex-
ERR
change
REC
units though
it is likely to
restore by
mounting
the unit
again.
When the
unit pro-
gram is nor-
Program
mally down-
loaded, the
error is re-
90
covered.
The error is
ERR
recovered
REC
when recon-
necting or
exchanging
it.
When the
ERR
commercial
REC
power is re-
stored, the
error is re-
covered.
The error is
ERR
recovered
REC
when
changing a
battery.
2-583

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents