Analog Trunk Data Setup - NEC SL2100 Programming Manual

Hide thumbs Also See for SL2100:
Table of Contents

Advertisement

SL2100
Level:
IN
Description
Use Program 14-02 : Analog Trunk Data Setup to set the basic options for each analog trunk port.
Program
Refer to the table below for a description of each option, its range and default setting.
14
Input Data
Item
No.
01
Signaling Type
(DP/DTMF)
02
Ring Detect Type 0 = Normal/delayed
03
Flash Type
04
Hooking Type
05
Dial Tone Detec-
tion for Manually
Accessed Trunks
06
Pause after First
Digit For Manual-
ly Dialed Calls
2-118
Program 14 : Trunk, Basic Setup
Trunk Port Number
Item
Input Data
0 = Dial Pulse (10 PPS)
2 = DTMF
1 = Immediate Ringing
0 = Open Loop Flash
1 = Ground
0 = Timed Flash (Hook-
ing)
1 = Disconnect (Cut)
0 = Dial Tone Detection
Not Used
1 = Dial Tone Detection
Used
0 = No Pause (No)
1 = Pause (Yes)

14-02 : Analog Trunk Data Setup

Description
This option sets the signaling type
for the trunk.
This option sets Extended Ring De-
tect or Immediate Ring Detect for
the trunk. For T1 loop/ground start
trunks, this option must be set to 1
for the trunks to ring and light cor-
rectly.
This option selects the flash type
(open loop flash or ground). Always
set this option for open loop flash.
This option lets you use Flash for
Timed Flash (Program 81-01-14) or
Disconnect (Program 81-01-15). (A
user implements Flash by pressing
the FLASH key while on a trunk
call.)
Use this option enable/disable dial
tone detection for directly accessed
trunks. If disabled, the system out-
dials on the trunks without monitor-
ing for dial tone.
Program 14 : Trunk, Basic Setup
ISSUE 2.0
1 ~ 128
Default
Related
Program
2
1
0
0
81-01-14
81-01-15
0
21-01-04
1
21-01-06

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents