System Options For Caller Id - NEC SL2100 Programming Manual

Hide thumbs Also See for SL2100:
Table of Contents

Advertisement

SL2100
Level:
IN
Description
Use Program 20-19 : System Options for Caller ID to define the system options for the Caller ID
Program
feature.
20
Input Data
Item
No.
01
Caller ID Display-
ing Format
02
Caller ID Wait
Timer
03
Caller ID Edit
Mode
04
Wait Facility IE
Timer
05
Caller ID Sender
Queuing Time
(Sender Wait)
07
Long Distance
Code
08
Area Code
09
Calling party
Name for ISDN
Trunk
Conditions
None
2-212
Program 20 : System Option Setup
Item
Input Data
0 = First 10 digits (Up-
per)
1 = Last 10 digits (Low-
er)
0 ~ 30 seconds
0 = Off
1 = On
0 ~ 64800 seconds
0 ~ 64800 seconds
Up to two digits
Up to six digits
Maximum of 12 digits
(0 ~ 9,
*
, #)

20-19 : System Options for Caller ID

Description
(if displaying digits are more than 12
digits)
When an incoming CO call is re-
ceived, the SL2100 starts the timer.
It will wait the programmed time for
Caller ID information from Telco be-
fore connecting the CO call.
If Caller ID Edit Mode is disabled
(0), no access code will be added to
the Caller ID. If this option is ena-
bled (1), the access code entered in
PRG 10-02-02 & 10-02-03 will be
added to the beginning of the Caller
ID.
This timer is used with ISDN trunks
to determine how long the system
waits for the Caller ID name from
the Telco.
When a name is programmed in this
program this will be the name sent
out for all callers that have PRG
15-01-10 enabled.
Program 20 : System Option Setup
ISSUE 2.0
Default
Related
Program
0
5
0
10
0
1
20-19-08
No Setting
20-19-07
No Setting

Hide quick links: