How to Use the Console
32-Bit Positioning Parameter
32-bit positioning parameter can be set.
<Notice>
Select an input digit (a dot blinks) by the [SHIFT] key and a parameter by the [UP]/[DOWN] key.
The 32-bit positioning parameter is shown on the two screens because of a large number of displayed
digits.
If the parameter is a negative value, a dot lights.
When you press the [SET] key, the parameter is modified.
* When you press
display is shown again.
* When you have set the parameters, write the parameters into EEPROM. If you turn the power supply
off before writing the parameters into EEPROM, those parameters are cleared.
94
Press
.
.....32.Pr00
.....32.Pr01
.....32.Pr05
during parameter setting, any parameter in process is not changed and "No."
Press
.
Selected 32.PrNo.
* The data is shown on the
two screens because of
a large number of displayed
digits.