When An Alarm Has Been Cleared (At Servo-On Command) - Panasonic MINAS A4P Series Instruction Manual

Panasonic ac servo motor and driver instruction manual
Table of Contents

Advertisement

Timing Chart

When an Alarm Has Been Cleared (at Servo-ON Command)

Alarm-clear input
(Refer to the following
for the input method.)
Dynamic brake
Motor energization
Brake release output
(BRK-OFF)
Servo-Alarm output
(ALM)
Homing command
(Input ON strobe signal,
after point specifying.)
Current position output
(P1OUT to P32OUT)
1) Alarm Clear can be input in the two ways below.
1. Point input (P1IN to P32IN: CN X5 Pin 3, 4, 5, 6, 7 and 8)
Specify the point "0" and, when 10 ms or more has passed, enable the strobe signal (STB: CN X5 Pin 24).
Alarm Clear is started when the disabled strobe signal input has been enabled.
2. Multi function input (EX-IN1/EX-IN2: CN X5 Pin 22/25)
Assign the Alarm Clear to the multi function input 1 (EX-IN1: CN X5 Pin 22) or multi function input 2 (EX-
IN2: CN X5 Pin 25) by SV.Pr5A (multi function input 1 signal selection) or SV.Pr5C (multi function input
2 signal selection) to enable the Alarm Clear.
Alarm Clear is started when the disabled strobe signal input has been enabled.
The signal logic of multi function input can be changed by SV.Pr59 (multi function input 1 signal logic) or
SV.Pr5B (multi function input 2 signal logic).
2) The servo driver power supply turns on again after an alarm is cleared.
A step operation can be performed by executing the homing.
When the homing has been completed, a transistor of the current position output (P1OUT to P32OUT: CN
X5 Pin 29, 30, 31, 32, 33 and 34) becomes a maximum point number decided by SV.Pr57 (selection of
number of input points).
However, in the absolute mode or if the homing is not required, a transistor of the current position output
(P1OUT to P32OUT: CN X5 Pin 29, 30, 31, 32, 33 and 34) becomes a maximum point number decided by
SV.Pr57 (selection of number of input points) immediately after Alarm Clear and the step operation can be
performed.
134
120ms or longer
clear
engaged
approx.40ms
not-energized
engaged (OFF)
not ready
not input
all OFF (Point 0)
approx.2ms
released
energized
released (ON)
approx.2ms
ready
100ms or longer
start to engage
homing
completed
maximum
point number