4.1. NOTE 9.1. KX-TDA0108XJ/X POWER UNIT TROUBLESHOOTING 61 4.2. SAFETY PRECAUTIONS 9.2. KX-TDA0104XJ/X POWER UNIT TROUBLESHOOTING 74 4.3. INSULATION RESISTANCE TEST 9.3. KX-TDA0103XJ/X POWER UNIT TROUBLESHOOTING 90 4.4. CAUTION 10 HOW TO REPLACE A FLAT PACKAGE IC 5 SPECIFICATIONS 10.1. PREPARATION 5.1.
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X 1 SUBJECT The power supply unit is to be changed to RoHS-compliant. Complete contents of the service manual will be revised in accordance with the change. 1.1. The Classification of Product The product should be classified by the "Model No."...
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X 2 ABOUT LEAD FREE SOLDER (PbF: Pb free) Note: In the information below, Pb, the symbol for lead in the periodic table of elements, will refer to standard solder or solder that contains lead.
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X 3 FOR SERVICE TECHNICIANS ICs and LSIs are vulnerable to static electricity. When repairing, the following precautions will help prevent recurring malfunctions. 1. Cover the plastic parts boxes with aluminum foil.
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X 5.2. SYSTEM CAPACITY 5.2.1. Power Supply Unit Selection Hybrid IP-PBX needs an optional power supply unit (PSU) suitable for its configuration. Calculate the amount of "load figures" from the type and number of equipment to be connected, and determine the type of PSU that will be required.
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X 6 INSTALLATION 6.1. INSTALLING/REPLACING THE POWER SUPPLY UNIT 6.1.1. Function PSU Type Lower/Upper Input Voltage Range Current Input Frequency PSU-S Lower: 100 V AC to 130 V AC 1.4 A...
Page 9
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X 6.1.2. Installing the Power Supply Unit 1. Insert the PSU along the guide rails. Caution: For safety reasons, do not touch parts in the PSU. 2. Push the release lever in the direction of the arrow, so that the PSU is made to engage with the connector on the back board securely.
Page 10
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X 6.1.3. Replacing the Power Supply Unit 1. Unplug the AC power cord and Back-up Battery Cable. 2. Turn the 4 screws anticlockwise to loosen them. 3. Pull the release lever in the direction of the arrow to disconnect the PSU from the back board.
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X 8 POWER SUPPLY UNIT CIRCUIT OPERATION The power unit supplies power to the various cards of the KX-TDA100, KX-TDA200 and KX-TDA600. The functions of the power unit are listed below.
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X 8.1. PSU-S (KX-TDA0108XJ/X) This power supply unit consists of two boards. 8.1.1. Block Diagram and Circuit Description of PSU-S [Block Diagram of PSU-S]...
Page 17
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X 8.1.1.1. AC Input ~ PFC Output This section explains about the operations of AC filter circuit, Rectifier circuit and PFC circuit. 1) Filter Circuit, Rectifier Circuit 1 The filter part eliminates the noise from power supply unit not to leak it out, and also the circuit prevents an incoming noise.
Page 18
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X 3) PFC Controller Circuit When the voltage is added to the Vcc terminal (Pin 8 of IC1) of PFC controller circuit, oscillation signal output (Pin 7 of IC1) is led to the PFC switching circuit, and switches the rectified DC voltage.
Page 19
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X 8.1.1.2. Main Converter This section mainly explains about the operation of main converter circuit which converts PFC output voltage to 41V (TYP.) output. 1) Switching Circuit This circuit uses Self-excited Pseudo Resonance Type Converter. This system supplies DC voltage through the following process: The DC voltage provided from the Rectifier and Smoothing Circuit is converted into RF pulse by switching ON/OFF MOS FET Q11 repeatedly.
Page 20
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X 3) Latch Circuit When secondary side protection circuit (Refer to Protection Circuit (P.29)) worked in abnormal state, the signal is sent to OVP terminal (Pin8 of IC2) of primary side through PC4. Therefore, switching operation of Q11 is stopped and the main converter operation is stopped.
Page 21
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X 8.1.1.3. Output voltage This section explains mainly about the operation of circuit which converts the main converter output to 15V, 15VPT, 30V and 41V, and also explains about the over current protector of each output.
Page 22
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X IC301 (on Sub board) Pin1 Compensating: Voltage error amplifier output Pin2 Voltage Feedback: Inverting input of the error amplifier Pin3 Current sence: Voltage proportional inductor current Pin4 Rt/Ct: Timing Resistor and Cap...
Page 23
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X 2) 15VPT Output 2-1) 15V PT Output During normal operation FET Q401 is ON and connected to 15V output. Then regulated 15V is output. At that time the comparator IC401 output is high, and the transistor Q402 is OFF.
Page 24
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X 3) 30V Output Voltage 3-1) 30V Output Converter Switching Circuit The main converter output voltage is stepped down by switching choke coil L202, FET Q202 and diode D210, and then smoothed by electrolytic capacitor C205.
Page 25
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X IC301 (on Sub board) Pin1 Compensating: Voltage error amplifier output Pin2 Voltage Feedback: Inverting input of the error amplifier Pin3 Current sence: Voltage proportional inductor current Pin4 Rt/Ct: Timing Resistor and Cap.
Page 26
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X 4) 41V Output Voltage 4-1) 41V Output During normal operation FET Q156 is ON. 41V output is connected to the main converter output, and the regulated output by the main converter is output.
Page 27
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X 8.1.1.4. Battery Voltage Input/Output This section explains about the operation of Battery Voltage Input/Output. 1) While Outputting the Battery Voltage (While charging) During normal operation FETs Q153 and Q155 of battery Input/Output DC switching circuit are ON and connected to the main converter to output the regulated main converter output voltage.
Page 28
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X 8.1.1.5. Alarm Signal Sending Circuit This section explains about the operation of the circuit that sends AC alarm/DC alarm. 1) Dropper Circuit The main converter output voltage is dropped to 27V by the constant voltage circuit consisting of Q521 and zener diode D521 to feed the power supply.
Page 29
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X 8.1.1.6. Protection Circuit This section explains about the Over Voltage Protection Circuit and Over Heat Protection Circuit and Battery Reverse Connection Protection Circuit. 1) Abnormal Condition Detection Circuit Abnormal condition detection circuit consists of thyristors Q524 and Q525 (on Sub board). When power supply operation becomes abnormal, the abnormal detection signal is sent and Q524 and Q525 are turned ON.
Page 30
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X 8.2. PSU-M (KX-TDA0104XJ/X) This power supply unit consists of four boards. 8.2.1. Block Diagram and Circuit Description of PSU-M [Block Diagram of PSU-M]...
Page 31
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X 8.2.1.1. AC Input ~ PFC Output This section explains about the operations of AC filter circuit, Rectifier circuit and PFC circuit. 1) Filter Circuit, Rectifier Circuit 1 The filter part eliminates the noise from power supply unit not to leak it out, and also the circuit prevents an incoming noise.
Page 32
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X 3) PFC Controller Circuit When the voltage is added to the Vcc terminal (Pin10 of IC051) of PFC controller circuit, oscillation signal output (Pin 8 of IC051) is led to the PFC switching circuit, and switches the rectified DC voltage.
Page 33
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X 8.2.1.2. Main Converter This section mainly explains about the operation of main converter circuit which converts PFC output voltage to 41V (TYP.) output. 1) Switching Circuit This circuit uses Self-excited Pseudo Resonance Type Converter. This system supplies DC voltage through the following process: The DC voltage provided from the Rectifier and Smoothing Circuit is converted into RF pulse by switching ON/OFF MOS FET Q601 repeatedly.
Page 34
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X 4) Discharge Circuit In case that the unit is turned ON after the latch circuit worked at abnormal condition, it is impossible to boot the unit unless the electric charge in the power supply is discharged. To save the waiting time for reboot, the unit has a discharge circuit consisting of Q610 and Q611.
Page 35
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X 8.2.1.3. Output voltage This section explains mainly about the operation of circuit which converts the main converter output to 15V, 15VPT, 30V and 41V, and also explains about the over current protector of each output.
Page 36
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X IC301 (on Sub board 2) Pin1 Compensating: Voltage error amplifier output Pin2 Voltage Feedback: Inverting input of the error amplifier Pin3 Current sence: Voltage proportional inductor current Pin4 Rt/Ct: Timing Resistor and Cap...
Page 37
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X 2) 15VPT Output During normal operation FET Q401 is ON and connected to 15V output. Then regulated 15V is output. At that time the comparator IC401 output is high, and the transistor Q402 is OFF. When the 15VPT goes into the over current condition, the voltage difference occurs at detection resistors R401, R402 and R403.
Page 38
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X 3) 30V Output Voltage 3-1) 30V Output Converter Switching Circuit The main converter output voltage is stepped down by switching choke coil L202, FET Q202 and diode D210, and then smoothed by electrolytic capacitor C205.
Page 39
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X IC201 (on Sub board 2) Pin1 Compensating: Voltage error amplifier output Pin2 Voltage Feedback: Inverting input of the error amplifier Pin3 Current sence: Voltage proportional inductor current Pin4 Rt/Ct: Timing Resistor and Cap.
Page 40
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X 4) 41V Output Voltage 4-1) 41V Output During normal operation FET Q156 is ON. 41V output is connected to the main converter output, and the regulated output by the main converter is output. Transformer T301 sub-winding voltage of 15V output converter is led to the voltage gate of Q156, and Q156 is turned ON.
Page 41
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X 8.2.1.4. Battery Voltage Input/Output This section explains about the operation of Battery Voltage Input/Output. 1) While Outputting the Battery Voltage (While charging) During normal operation FETs Q153 and Q155 of battery Input/Output DC switching circuit are ON and connected to the main converter to output the regulated main converter output voltage.
Page 42
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X 8.2.1.5. Alarm Signal Sending Circuit This section explains about the operation of the circuit that sends AC alarm/DC alarm. 1) Dropper Circuit The main converter output voltage is dropped to 27V by the constant voltage circuit consisting of Q521 and zener diode D521 to feed the power supply.
Page 43
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X 8.2.1.6. Protection Circuit This section explains about the Over Voltage Protection Circuit and Over Heat Protection Circuit and Battery Reverse Connection Protection Circuit. 1) Abnormal Condition Detection Circuit Abnormal condition detection circuit consists of thyristors Q524 and Q525 (on Sub board 2). When power supply operation becomes abnormal, the abnormal detection signal is sent and Q524 and Q525 are turned ON.
Page 44
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X 4) Over Voltage Protection Circuit When any of 15V, 15VPT, 30V and main converter 41V output becomes abnormal, the voltage is sent to the abnormal detection circuit through zener diode D529 (on Sub board 2).
Page 45
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X 8.3. PSU-L (KX-TDA0103XJ/X) This power supply unit consists of four boards. 8.3.1. Block Diagram and Circuit Description of PSU-L...
Page 46
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X 8.3.1.1. AC Input ~ PFC Output This section explains about the operations of AC filter circuit, Rectifier circuit and PFC circuit. 1) Filter Circuit, Rectifier Circuit 1 The filter part eliminates the noise from power supply unit not to leak it out, and also the circuit prevents an incoming noise.
Page 47
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X 3) PFC Controller Circuit When the voltage is added to the Vcc terminal (Pin 10 of IC051) of PFC controller circuit, oscillation signal output (Pin 8 of IC051) is led to the PFC switching circuit, and switches the rectified DC voltage.
Page 48
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X 8.3.1.2. Main Converter This section mainly explains about the operation of main converter circuit which converts PFC output voltage to 41V (TYP.) output and also about the latch circuit and discharge circuit.
Page 49
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X electric charge in the power supply is discharged. To save the waiting time for reboot, the unit has a discharge circuit consisting of Q610 and Q611. Refer to Fig. 2 (F)
Page 50
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X 8.3.1.3. Output voltage This section explains mainly about the operation of circuit which converts the main converter output to 15V, 15VPT, 30V and 41V, and also explains about the over current protector of each output.
Page 51
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X IC301(on Sub board2) Pin1 Compensating: Voltage error amplifier output Pin2 Voltage Feedback: Inverting input of the error amplifier Pin3 Current sence: Voltage proportional inductor current Pin4 Rt/Ct: Timing Resistor and Cap...
Page 52
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X 2) 15V PT Output 2-1) 15V PT Output Converter Switching Circuit The main converter output voltage is stepped down by switching choke coil L402, FET Q401 and diodes D412 and D414, and then smoothed by electrolytic capacitors C417, C418 and C419.
Page 54
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X 3) 30V Output Voltage (Sub board4) 3-1) 30V Output Converter Switching Circuit The main converter output voltage is stepped down by switching choke coil L202, FET Q202 and diode D210, and then smoothed by electrolytic capacitor C205.
Page 55
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X IC201(on Sub board4) Pin1 Compensating: Voltage error amplifier output Pin2 Voltage Feedback: Inverting input of the error amplifier Pin3 Current sence: Voltage proportional inductor current Pin4 Rt/Ct: Timing Resistor and Cap.
Page 56
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X 4) 41V Output Voltage 4-1) 41V Output During normal operation FET Q401 is ON. 41V output is connected to the main converter output, and the regulated output by the main converter is output.Transformer T301 sub-winding voltage of 15V output converter is led to the voltage gate of Q156, and Q156 is turned ON.
Page 57
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X 8.3.1.4. Battery Voltage Input/Output This section explains about the operation of Battery Voltage Input/Output. 1) While Outputting the Battery Voltage (While charging) During normal operation FETs Q153 and Q155 of battery Input/Output DC switching circuit are ON and connected to the main converter to output the regulated main converter output voltage.When the battery switch SW501 is turned ON and CN102 is...
Page 58
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X 8.3.1.5. Alarm Signal Sending Circuit This section explains about the operation of the circuit that sends AC alarm/DC alarm. 1) Dropper Circuit The main converter output voltage is dropped to 27V by the constant voltage circuit consisting of Q521 and zener diode D521 to feed the power supply.
Page 59
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X 8.3.1.6. Protection Circuit This section explains about the Over Voltage Protection Circuit, Over Heat Protection Circuit and Battery Reverse Connection Protection Circuit. 1) Abnormal Condition Detection Circuit Abnormal condition detection circuit consists of thyristors Q524 and Q525 (on Sub board2).When power supply operation becomes abnormal, the abnormal detection signal is sent and Q524 and Q525 are turned ON.
Page 60
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X 4) Over Voltage Protection Circuit When any of 15V, 15VPT, 30V and main converter 41V output becomes abnormal, the voltage is sent to the abnormal detection circuit through zener diode D529 (on Sub board2).
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X 9 TROUBLESHOOTING GUIDE 9.1. KX-TDA0108XJ/X POWER UNIT TROUBLESHOOTING 9.1.1. No Voltage is Output at All (1) (Output voltage of Main Converter is Abnormal)
Page 62
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X 9.1.2. No Voltage is Output at All (2) (Output voltage of Main Converter is Normal) 9.1.3. +15VPT, +30V, +41V are Not Output (Only +15V is output) 9.1.4. +15VPT, +30V are Not Output (+15V, +41V are available)
Page 63
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X 9.1.5. Only +15VPT is Not Output (Other Voltage are available) 9.1.6. Only +30V is Not Output (Other Voltage are available) 9.1.7. Only +41V is Not Output (Other Voltage are available)
Page 64
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X 9.1.8. Battery Backup Function Does Not Operate / PSU can Not Charge Batteries 9.1.9. AC Alarm is Sent (Although AC Power is Normal) 9.1.10. DC Alarm is Sent (Although All DC Output are Normal)
Page 65
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X 9.1.11. Table 1 Ref. Defective mode Check Point The parts which have the possibility of failure simultaneously Short/Open BEA4 Open Short C101 Short C104 Short C105 Short Short Short...
Page 66
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X Ref. Defective mode Check Point The parts which have the possibility of failure simultaneously Short/Open D325 Short D311 D419 Short D510 Short D529 Short D651 Open D651 Short D654...
Page 67
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X Ref. Defective mode Check Point The parts which have the possibility of failure simultaneously Short/Open Q301 Short Q301 Short Q302 Open Q302 Open Q302 Open Q302 Short Q302 Short...
Page 68
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X Ref. Defective mode Check Point The parts which have the possibility of failure simultaneously Short/Open Open Open Short Open Short Open Open Short Open Open Open Open Short Short...
Page 69
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X Ref. Defective mode Check Point The parts which have the possibility of failure simultaneously Short/Open Open Short Open Open Open Open Open Short Short Short Open Open Short Open...
Page 70
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X 9.1.15. Table 5 Ref. Defective mode Check Point The parts which have the possibility of failure simultaneously Short/Open C305 Open C405 Short C411 Open C411 Short CN101 Open 15VPT...
Page 71
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X Ref. Defective mode Check Point The parts which have the possibility of failure simultaneously Short/Open Q201 Short Q201 Short Q202 Open Q202 Open Q202 Open Q202 Short Q203 Short...
Page 72
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X 9.1.17. Table 7 Ref. Defective mode Check Point The parts which have the possibility of failure simultaneously Short/Open C164 Short C165 Short C314 Short C660 Short CN101 Open CN101...
Page 73
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X 9.1.18. Table 8 Ref. Defective mode Check Point The parts which have the possibility of failure simultaneously Short/Open BEA155 Open C501 Short CN102 Open CN102 Open CN102 Open CN102...
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X 9.2. KX-TDA0104XJ/X POWER UNIT TROUBLESHOOTING 9.2.1. No Voltage is Output at All (1) (Output voltage of Main Converter is Abnormal)
Page 75
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X 9.2.2. No Voltage is Output at All (2) (Output voltage of Main Converter is Normal) 9.2.3. +15VPT, +30V, +41V are Not Output (Only +15V is output)
Page 76
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X 9.2.4. +15VPT, +30V are Not Output (15V, +41V are available) 9.2.5. Only +15VPT is Not Output (Other Voltage are available)
Page 77
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X 9.2.6. Only +30V is Not Output (Other Voltage are available) 9.2.7. Only +41V is Not Output (Other Voltage are available)
Page 78
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X 9.2.8. Battery Backup Function Does Not Operate/PSU can Not Charge Batteries. 9.2.9. AC Alarm is Sent (Although AC Power is Normal)
Page 79
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X 9.2.10. DC Alarm is Sent (Although All DC Output are Normal) 9.2.11. Table 1 Ref. Defective mode Check Point The parts which have the possibility of failure simultaneously Short/Open...
Page 80
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X Ref. Defective mode Check Point The parts which have the possibility of failure simultaneously Short/Open C209 Short C304 Short C306 Short C308 Short D311 C310 Short C313 Open C313...
Page 81
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X Ref. Defective mode Check Point The parts which have the possibility of failure simultaneously Short/Open D673 Short D693 Open Open IC051 Open IC051 Short IC051 Short IC051 Short IC051...
Page 82
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X Ref. Defective mode Check Point The parts which have the possibility of failure simultaneously Short/Open Open Short Short Short Short Open Short Open Open Short Open Open Open Short...
Page 83
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X Ref. Defective mode Check Point The parts which have the possibility of failure simultaneously Short/Open Q610 Short Q610 Short Q610 Open Q610 Open Q610 Open Q611 Short Q611 Short...
Page 84
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X Ref. Defective mode Check Point The parts which have the possibility of failure simultaneously Short/Open R311 Open R312 Open R313 Open R313 Short R314 Open R314 Short R316 Open...
Page 85
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X Ref. Defective mode Check Point The parts which have the possibility of failure simultaneously Short/Open VR652 Open Short Short 9.2.12. Table 2 Ref. Defective mode Check Point The parts which have the possibility of failure simultaneously...
Page 86
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X 9.2.15. Table 5 Ref. Defective mode Check Point The parts which have the possibility of failure simultaneously Short/Open C305 OPEN C405 Short C411 SHORT C411 OPEN CN101 OPEN CN101...
Page 87
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X Ref. Defective mode Check Point The parts which have the possibility of failure simultaneously Short/Open L202 OPEN L202 SHORT Q201 SHORT Q201 SHORT Q202 OPEN Q202 OPEN Q202 OPEN...
Page 88
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X 9.2.17. Table 7 Ref. Defective mode Check Point The parts which have the possibility of failure simultaneously Short/Open C164 SHORT C165 SHORT C314 SHORT CN101 OPEN CN101 SHORT 41V-GND...
Page 89
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X 9.2.18. Table 8 Ref. Defective mode Check Point The parts which have the possibility of failure simultaneously Short/Open BEA11 OPEN BEA12 OPEN C501 SHORT C660 SHORT CN102 OPEN CN102...
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X 9.3. KX-TDA0103XJ/X POWER UNIT TROUBLESHOOTING 9.3.1. No Voltage is Output at All (1) (Output voltage of Main Converter is Abnormal)
Page 91
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X 9.3.2. No Voltage is Output at All (2) (Output voltage of Main Converter is Normal) 9.3.3. +15VPT, +30V, +41V are Not Output (Only +15V is output)
Page 92
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X 9.3.4. +15VPT, +30V are Not Output (+15V,+41V are available) 9.3.5. Only +15VPT is Not Output (Other Voltage are available)
Page 93
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X 9.3.6. Only +30V is Not Output (Other Voltage are available) 9.3.7. Only +41V is Not Output (Other Voltage are available)
Page 94
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X 9.3.8. Battery Backup Function Does Not Operate /PSU can Not Charge Batteries. 9.3.9. AC Alarm is Sent (Although AC Power is Normal)
Page 95
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X 9.3.10. DC Alarm is Sent (Although All DC Output are Normal)
Page 96
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X 9.3.11. Table 1 Ref. Defective mode Check Point The parts which have the possibility of failure simultaneously Short/Open C017 Short C018 Open C018 Short C019 Short C020 Short C021...
Page 97
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X Ref. Defective mode Check Point The parts which have the possibility of failure simultaneously Short/Open CN301 Short CN301 Short CN401 Short CN801 Open CN801 Short CN803 Short CN803 Short...
Page 98
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X Ref. Defective mode Check Point The parts which have the possibility of failure simultaneously Short/Open IC051 Open IC051 Open IC051 Open IC051 Open IC051 Open IC051 Open IC051 Short...
Page 99
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X Ref. Defective mode Check Point The parts which have the possibility of failure simultaneously Short/Open Q302 Short Q302 Short Q302 Short Q303 Short Q304 Open Q304 Open Q304 Open...
Page 100
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X Ref. Defective mode Check Point The parts which have the possibility of failure simultaneously Short/Open Q620 Open Q620 Short Q620 Short Q601 Q620 Short Q601 Q622 Q622 Open Q622...
Page 101
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X Ref. Defective mode Check Point The parts which have the possibility of failure simultaneously Short/Open Short R525 Short D510 R526 Short D510 Open Short Open Open Open Short R599...
Page 102
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X Ref. Defective mode Check Point The parts which have the possibility of failure simultaneously Short/Open Short 9.3.12. Table 2 Ref. Defective mode Check Point The parts which have the possibility of failure simultaneously...
Page 103
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X Ref. Defective mode Check Point The parts which have the possibility of failure simultaneously Short/Open D416 Open D423 Short D431 Short IC401 Open IC401 Open IC401 Open IC401 Open...
Page 104
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X Ref. Defective mode Check Point The parts which have the possibility of failure simultaneously Short/Open T402 Open T402 Short T402 Short 9.3.16. Table 6 Ref. Defective mode Check Point...
Page 105
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X 9.3.17. Table 7 Ref. Defective mode Check Point The parts which have the possibility of failure simultaneously Short/Open C164 Short C314 Short R319 C656 Short C660 Short CN101 Open...
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X 11.5. EXTENSION CORD FOR SERVICING Note: Internal extension cords that enable the Power Supply Unit to be operated while it is disassembled.
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X 13 REPLACEMENT PARTS LIST Note: 13.1.2. Accessories and Packing Materials 1. RTL (Retention Time Limited) Ref. Part No. Part Name & Description Remarks The marking (RTL) indicates that the Retention Time is limited for this item.
Page 116
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X Ref. Part No. Part Name & Description Remarks Ref. Part No. Part Name & Description Remarks D2064AQ210 DIODE(SI) C105 C30A0FQ181 D101 D2022BQ003 DIODE(SI) C162 C1132EC104 D155 D2095AQ008 DIODE(SI) C163...
Page 117
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X Ref. Part No. Part Name & Description Remarks Ref. Part No. Part Name & Description Remarks R3120TC103 R301 R3131AC102 R3121TC102 R302 R3067DQR22 0.22 R3121TC103 R303 R3067DQR22 0.22 R3123TC184 180k...
Page 118
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X Ref. Part No. Part Name & Description Remarks Ref. Part No. Part Name & Description Remarks (FILTERS) D2095AQ008 DIODE(SI) L1179JL402 MECHANICAL FILTER D2095AQ008 DIODE(SI) L1179JL402 MECHANICAL FILTER D4103AC007 DIODE(SI)
Page 119
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X Ref. Part No. Part Name & Description Remarks Ref. Part No. Part Name & Description Remarks C330 C1132EC104 R427 R3121TC561 C511 C1132EC104 R428 R3121TC561 C519 C1132EC104 R515 R3121TC561 C520...
KX-TDA0103XJ / KX-TDA0104XJ / KX-TDA0108XJ / KX-TDA0103X / KX-TDA0104X / KX-TDA0108X 14 FOR THE SCHEMATIC DIAGRAM Note: 1. DC voltage measurements are taken with an oscilloscope or a tester with a ground. 2. The schematic diagrams and circuit board may be modified at any time with the development of new technology.