Panasonic MINAS A4P Series Instruction Manual page 71

Panasonic ac servo motor and driver instruction manual
Table of Contents

Advertisement

Servo
Title
PrNo.
6C
External
*
regenerative
resistor set up
6D
Main power-off
*
detection time
6E
Emergency stop
torque set up
Parameters for Protective function
Servo
Title
PrNo.
70
Position deviation
error level
72
Overload level
Setup
Unit
range
With this parameter, you can select either to use the built-in regenerative
0 to 3
resistor of the driver, or to separate this built-in regenerative resistor and
for
externally install the regenerative resistor (between RB1 and RB2 of
A, B-frame
Connector CN X2 in case of A to D-frame, between P and B2 of terminal
<3>
block in case of E, F-frame).
for
Setup value
C to F-frame
<0>
<0>
(C, D, E and
F-frame)
1
2
<3>
(A, B-frame)
<Remarks>
Install an external protection such as thermal fuse when you use the
external regenerative resistor.
Otherwise, the regenerative resistor might be heated up abnormally and
result in burnout, regardless of validation or invalidation of regenerative
over-road protection.
<Caution>
When you use the built-in regenerative resistor, never to set up other
value than 0. Don't touch the external regenerative resistor.
External regenerative resistor gets very hot, and might cause burning.
35 to 1000
2ms
You can set up the time to detect the shutoff while the main power is kept
<35>
shut off continuously.
The main power off detection is invalid when you set up this to 1000.
0 to 500
%
You can set up the torque limit in case of emergency stop as below.
• During deceleration with the setup of 8 or 9 of SV.Pr67 (Error response
<0>
at main power-off)
• During deceleration with the setup of 8 or 9 of SV.Pr69 (Sequence at
Servo-OFF)
Normal torque limit is used by setting this to 0.
<Caution>
The stop is not due to the emergency stop input (EMG-STP: CN X5 Pin 2).
Setup
Unit
range
0 to 32767
256 x
• You can set up the excess range of position deviation.
<25000>
pulse
• Set up with the encoder pulse counts at the position control and with the
external scale pulse counts at the full-closed control.
• Err24 (Position deviation excess protection) becomes invalid when you
set up this to 0.
0 to 500
%
• You can set up the over-load level. The overload level becomes 115 [%]
<0>
by setting up this to 0.
• Use this with 0 setup in normal operation. Set up other value only when
you need to lower the over-load level.
• The setup value of this parameter is limited by 115[%] of the motor rating.
Function/Content
Regenerative resistor
Regenerative processing and
to be used
regenerative resistor overload
Regenerative processing circuit will be
activated and regenerative resistor overload
Built-in resistor
protection will be triggered according to the
built-in resistor (approx. 1% duty).
The driver trips due to regenerative overload
protection
External resistor
processing circuit is activated and its active
ratio exceeds 10%,
Regenerative processing circuit is activated,
but no regenerative over-load protection is
External resistor
triggered.
Both regenerative processing circuit and
regenerative protection are not activated, and
No resistor
built-in capacitor handles all regenerative
power.
Function/Content
[Setting]
Standard default : < >
(Err18),
when
regenerative
Standard default : < >
71