3.3.2 Control Signal Wiring
Connect wires to the control connector for remote operation and remote monitoring.
Tables 3.3 and 3.4 and Figs 3.2 show the pin assignments.
Fig 3.2 15 Pin D Sub-Miniature Female Receptacle
Pin. No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
PM10U
8
15
(As seen from connecting side)
Table 3.3 Control Connector Pin Assignments
Signal name
PUMP START (+)
RESET (+)
PUMP START/STOP
STATUS (+)
RESERVED (+)
WARNING STATUS (+)
ALARM STATUS (+)
REMOTE STATUS (+)
−
PUMP START (−)
RESET (−)
PUMP START/STOP
STATUS (−)
RESERVED (−)
WARNING STATUS (−)
ALARM STATUS (−)
REMOTE STATUS (−)
PUMP START/STOP, RESET request continuing signal input over 300ms.
Screw lock size : #4-40UNC
1
9
Contact pin surface : Au
I/O
IN
IN
OUT
OUT
OUT
OUT
OUT
Signal type
Run: CLOSE, Alternate
Reset: CLOSE, Alternate
Run: CLOSE, Alternate
WARNING: OPEN, Alternate
ALARM; OPEN, Alternate
REMOTE: CLOSE