Installation; Location - EBARA EV-PA 250 Instruction Manual

Dry vacuum pump
Table of Contents

Advertisement

24
P.

3. Installation

Choose the parts suitable for use condition in the piping and a seal part. Pump performance is changed
by the setting conditions such as the size / length of pump Iinlet / outlet.

3.1 Location

(1) This pump is designed for indoor installation. To install the pump, select a place following
enviromental condition. Also allow for sufficient space to ensure easy pump installation and
disassembly for maintenance.
Do not install the pump in the environment exposed rain, snow, ice or dust.
!
Install pump in a location at an ambient not exceeding 30°C. Particular caution is required
when the pump is operated in an enclosed room.
!
Vents at both ends of the pump. Place the pump at least 100mm from the stationary section.
If the cooling air supply is insufficient, the pump temperature will rise and problems such as
rotor contact will occur.
!
Do not to overturn the pump when pushing and pulling it sideways, because the width of the
pump is small to its height.
!
Do not step on the pump or place objects on it.
(2) Rubber feet of five each are attaches under the pump base. To fix the pump, install the pump
on flat surface.
Note
To fix the pump, the rubber feet of five each attaches. If the pump is not stable, vibration and
noise of the pump may be increased.
PM10U
Area of use:
Indoor Use only
Ambient temperature: 5℃ to 30℃
Humidity
:
80% or less
Altitude restriction:
Max. 2000m
Pollution:
Pollution degree 2
CAUTION
CAUTION
CAUTION
CAUTION
EBARA
CORPORATION