Sense Function (Sense) - ITech IT6000C Series User Manual

Bi-directional programmable dc power supply
Hide thumbs Also See for IT6000C Series:
Table of Contents

Advertisement

4. After the parameter settings are complete, press [Enter].

5.7 Sense Function (Sense)

This menu item is used to switch the power supply to local measurement or re-
mote sensing.
The IT6000C series power supply supports two connection methods: Local
measurement and Remote sensing. The remote sensing is used for maximizing
measurement accuracy. (Refer to
The procedures to set the menu item are as follows.
1. Press the composite keys [Shift]+[P-set] (System) on the front panel to en-
2. Press the Up/Down key or turn the knob to select the Sense and press
3. Press the Left / Right key or turn the knob to adjust the value of this
4. After the parameter settings are complete, press [Enter].
Category
Parameter
Speed
V-Rise Time/I-Rise Time
V-Fall Time/I-Fall Time
Output Res
On Delay/Off Delay
Last: Indicates when powered on, the instrument will remain the same
parameter settings and output status as last time you powered off the
instrument.
Last+Off: Indicates when powered on, the instrument will remain the
same settings as last time you powered off the instrument, but the output
status is Off.
For example, Last is selected, and the voltage value is set to 20V. After the
instrument is powered off and then powered on, the voltage displayed on the
interface is 20V.
ter the system menu.
[Enter].
parameter.
Off: Default value, indicates turn the sense function off.
On: Indicates turn the sense function on.
Copyright © Itech Electronic Co., Ltd.
2.4 Connecting the Device Under Test
Basic Operation
Initial Value
High
0.1s
1000
0
(DUT))
120