ITech IT6000C Series User Manual page 53

Bi-directional programmable dc power supply
Hide thumbs Also See for IT6000C Series:
Table of Contents

Advertisement

If the instrument is the cabinet type, the rear panel of the cabinet provides a
master power switch. The relationships between the device status and switch
status are listed in the following table.
Master switch status
On
On
Off
Off
Turning the POWER Switch On / Off
Self-Test Procedures
A successful self-test indicates that the purchased product meets delivery
standards and it is available for normal usage. Normal self-test procedures:
1. Correctly connect the power cord and power on the instrument.
2. After the instrument is self-tested normally, the VFD shows the output volt-
If an error occurs during the self-test, an error message is displayed. The follow-
ing table lists the error messages you might see.
Turning the POWER Switch On
Check that the power cord is connected properly.
Flip the POWER switch to the ( | ) side to turn the instrument on. The front
panel display will light up after a few seconds. It may take about 30 seconds
or so for the power supply to initialize before it is ready for use.
Turning the POWER Switch Off
Flip the POWER switch to the ( O ) side to turn the instrument off. After you
turn the POWER switch off, wait at least 10 seconds after the fan stops be-
fore you turn the POWER switch back on. Turning the instrument on too
soon after you turn it off can cause damage to the inrush current limiter cir-
cuit, as well as reduce the life of components such as the POWER switch
and the internal input fuses.
The instrument starts the self-test.
age, current, power and other information (CV mode).
Copyright © Itech Electronic Co., Ltd.
Desperate switch
status
On
Off
On
Off
Getting Started
Device status
On
Off
Off
Off
41

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IT6000C Series and is the answer not in the manual?

Questions and answers

Table of Contents